Electrical Installation 115 VAC and 230 VAC
The 115 VAC models (260101 and 260102) come wired with a short power cord and a grounded electrical plug. Power to the unit must be 115 VAC single phase. If an extension cord is required, it should be a
The 230 VAC model (260104) is not shipped with a power cord and plug. You must pur- chase and install an appropriate power cord and plug that meets your local electrical codes.
Electrical Installation 12 VDC
The 12 VDC model (260100) is not shipped with a power cord since the installation will determine the length of the power cord.
1.Verify the on/off switch is in the off position.
2.Remove the wiring junction box cover by removing the four screws.
3.Use 10 AWG wire to connect the red (+) and black
4.Reattach the wiring junction box cover with the four screws.
Operation
Operation
CAUTION
Do not operate pump dry. Do not run pump for more than 5 minutes with nozzle closed.
See Parts, page 8 for items referenced in
parentheses, i.e., (17).
1.On/Off switch is located on the motor (9). Move switch to ON position.
2.Insert nozzle into container or fill tube and open nozzle to dispense fluid.
3.Close nozzle to stop flow. The pump has an internal bypass valve that will bypass the fluid internally with nozzle closed.
4.Immediately after dispensing, turn switch to OFF position.
Pressure Relief Procedure
1.Verify pump switch is OFF.
2.Open nozzle to relieve any residual pres- sure.
3.To prevent damage to the pump, use inlet suction screen (260306) when pumping used oils.
311305E | 5 |