State Industries SUF-130-300, SUF-130-400 warranty Rough-In-Dimensions, Foreword

Page 2

ROUGH-IN-DIMENSIONS

GAS VALVE PIPING

SUF 130-300 1 1/4" NPT

SUF 130-400 1 1/4" NPT

TABLE 1 RECOVERY CAPACITIES.

 

 

 

 

 

 

 

U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED

 

 

 

TYPE OF

INPUT

Approx.

20F°

30F°

40F°

50F°

60F°

70F°

80F°

90F°

100F°

110°

120F°

 

130F°

140F°

MODEL

GAS

BTUH

KW

Capacity

11C°

17C°

22C°

28C°

33C°

39C°

44C°

50C°

56C°

61C°

67C°

 

72C°

78C°

SUF 130-300

NATURAL

300,000

 

 

130 US Gals.

GPH

1746

1164

873

699

582

499

436

388

349

318

291

 

269

250

 

88

 

492 Litres

LPH

6610

4406

3304

2644

2203

1888

1652

1469

1322

1201

1102

 

1017

945

 

 

 

 

 

SUF 130-300

PROPANE

300,000

 

 

130 US Gals.

GPH

1746

1164

873

699

582

499

436

388

349

318

291

 

269

250

 

88

 

492 Litres

LPH

6610

4406

3304

2644

2203

1888

1652

1469

1322

1201

1102

 

1017

945

 

 

 

 

 

SUF 130-400

NATURAL

399,900

 

 

130 US Gals.

GPH

2328

1552

1164

931

776

665

582

517

466

423

388

 

359

332

 

117

 

492 Litres

LPH

8813

5875

4406

3525

2938

2518

2203

1958

1763

1602

1469

 

1356

1259

 

 

 

 

 

SUF 130-400

PROPANE

399,900

 

 

130 US Gals.

GPH

2328

1552

1164

931

776

665

582

517

466

423

388

 

359

332

 

117

 

492 Litres

LPH

8813

5875

4406

3525

2938

2518

2203

1958

1763

1602

1469

 

1356

1259

 

 

 

 

 

Recovery capacities are based on heater performance at 96% thermal efficiency for SUF 300 and 400.

FOREWORD

These designs comply with the current edition of the American

National Standard for Gas Water Heaters, Volume III,

ANSI Z21.10.3 / CSA 4.3 as an automatic circulating tank water heater, and automatic storage water heaters.

Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and methods of piping necessary. It is highly essential that all water, gas piping and wiring be installed as shown on the

diagrams.

Particular attention should be given to the installation of thermometers at the locations indicated on the diagrams as these are necessary for checking the proper functioning of the heater.

In addition to these instructions, the equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.

In the absence of local codes, the installation must comply with the current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the National Electrical Code, NFPA 70 or CAN/CSA-B149.1, the Natural Gas and Propane Installation Code and CSA C22.1, the Canadian Electrical Code. All documents are available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131. NFPA documents are also available from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

Image 2
Contents Commercial GAS Water Heater ROUGH-IN-DIMENSIONS ForewordTable of Contents FeaturesAT a Glance Quick Installation Tips Horizontal Sidewall Venting Vertical Rooftop VentingDishwashing Machine Requirement Water Temperature Setpoint Adjustment ProcedureHigh Limit Switch E.C.O Required Ability Installation InstructionsCirculating Pump Insulation BlanketsAIR Requirements ClearancesHard Water Unconfined SpaceInstallation of Carbon Monoxide Detectors VentingCanadian Direct Vent US Horizontal Vent Direct Venting Direct Vent Terminal InstallationVent Pipe Termination 3x 4 PVC Reducer with Intake ScreenInstallation Sequence Vertical Vent Terminal InstallationInstallation of Vent System Vent Length TableControls and Switches Connection of GAS Pipe GAS PipingHOT Surface Igniter System Connections Heater Wiring Water Potable Heating and Space HeatingSUF 130-300 Wiring Diagram SUF 130-400 Wiring Diagram Sequence of Operation OperationElectronic Control OverviewAdjusting the Operating Set Point Example of a Warning Fault and Warning ConditionsChanging the Display Units Example of a Fault Advanced Diagnostics Information Access to the Current Fault or WarningViewing the Fault History Viewing Information About the HeaterOperating Instructions Prior to Start UP Required AbilityOperating Instructions Maintenance General InformationSediment Removal FlushingDraining Lime Scale RemovalVent System Powered Anode SystemDrain Valve and Access Panels Installation Diagrams Page Must be Identical Heaters Pipe Relief Valve to Open Drain Page Multiple Unit Installations Troubleshooting Motor will not RUN Motor RUNS, Burner Lights Momentarily Then Locks OUTGAS Fails to Shut OFF Replacement PartsNoisy Burner Operation Model SUF-130-300/400 NEA /PEA Limited Warranty Tank