State Industries SSE-120, SSE-5 warranty Electrical, Branch Circuit

Page 13

ELECTRICAL

GENERAL

The installation must conform to these instructions, the local code authority having jurisdiction, and the requirements of the power company. In the absence of code requirements follow the latest version of NFPA-70, The National Electrical Code which may be ordered from: American National Standards Institute, 1430 Broadway, New York, NY 10018.

Voltage applied to the heater should not vary more than +5% to -10% of the model and rating plate marking for satisfactory operation.

DO NOT ENERGIZE THE BRANCH CIRCUIT FOR ANY REASON BEFORE THE HEATER TANK IS FILLED WITH WATER. DOING SO WILL CAUSE THE HEATING ELEMENT TO BURN OUT.

The branch circuit is connected to the heater wiring through an opening provided on the heater.

WARNING

AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF ELECTRIC SHOCK OR POSSIBLE ELECTROCUTION. The water heater should be connected to a separate, grounded, branch circuit with overcurrent protection and disconnect switch. The water heater should be grounded in accordance with national and local codes.

Check the heater model and rating plate information against the characteristics of the branch circuit electrical supply. DO NOT CONNECT THE HEATER TO AN IMPROPER SOURCE OF ELECTRICITY.

BRANCH CIRCUIT

The branch circuit wire and fuse size should be established through reference to the latest version of the National Electrical Code or other locally approved source in conjunction with the heater amperage rating. Branch circuit wires should be 75°C temperature rated. For convenience, portions of the wire size tables from the Code are reproduced here. It is suggested the electrician size the branch circuit at 125 percent of the heater ampere rating and further increase wire size as necessary to compensate for voltage drop in long runs. Branch circuit voltage drop should not exceed 3% at the heater.

TABLE 310-16. Allowable Ampacities of Insulated Conductors

Not More Than Three Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F)

Size

 

 

Temperature Rating of Conductor, See table 310-13

 

 

Size

 

 

 

 

 

 

 

 

 

 

 

 

60°C

75°C

85°C

90°C

60°C

75°C

 

85°C

90°C

 

 

(140°F)

(167°F)

(185°F)

(194°F)

(140°F)

(167°F)

 

(185°F)

(194°F)

 

 

TYPES

TYPES

TYPES

TYPES

TYPES

TYPES

 

TYPES

TYPES

 

 

RUW, T

FEPW

V, MI

TA, TBS

RUW, T

RH, RHW

 

V, MI

TA, TBS,

 

AWG

TW, UF

RH,RHW

 

SA, AVB

TW, UF

RUH

 

 

SA, AVB

 

 

 

RUH,

 

SIS, =FEP,

 

THW,

 

 

SIS,

AWG

 

 

THW,

 

=FEPB,

 

THWN

 

 

=RHH,

 

MCM

 

THWN,

 

=RHH,

 

XHHW,

 

 

=THHN,

MCM

 

 

XHHW

 

=THHN,

 

USE

 

 

=XHHW*

 

 

 

USE, ZW

 

=XHHW*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

……

……

……

21

……

……

 

……

……

……

16

……

……

22

22

……

……

 

……

……

……

14

15

15

25

25

……

……

 

……

……

……

12

20

20

30

30

15

15

 

25

25

12

10

30

30

40

40

25

25

 

30

30

10

8

40

45

50

50

30

40

 

40

40

8

6

55

65

70

70

40

50

 

55

55

6

4

70

85

90

90

55

65

 

70

70

4

3

80

100

105

105

65

75

 

80

80

3

2

 

115

120

120

75

90

 

95

95

2

1

 

130

140

140

 

100

 

110

110

1

0

 

150

155

155

 

120

 

125

125

0

00

 

175

185

185

 

135

 

145

145

00

000

 

200

210

210

 

155

 

165

165

000

0000

 

230

235

235

 

180

 

185

185

0000

250

 

255

270

270

 

205

 

215

215

250

300

 

285

300

300

 

230

 

240

240

300

350

 

310

325

325

 

250

 

260

260

350

400

 

335

360

360

 

270

 

290

290

400

500

 

380

405

405

 

310

 

330

330

500

 

 

 

 

 

 

 

 

 

 

 

Ambient

 

 

 

 

 

 

 

 

 

Ambient

Temp.°C

 

 

 

 

 

 

 

 

 

Temp.°F

31-40

.82

.88

.90

.91

.82

.88

 

.90

.91

86-104

41-50

.58

.75

.80

.82

.58

.75

 

.80

.82

105-122

51-60

……

.58

.67

.71

……

.58

 

.67

.71

123-141

61-70

……

.35

.52

.58

……

.35

 

.52

.58

142-158

71-80

……

……

.30

.41

……

……

 

.30

.41

159-176

=The load current rating and the overcurrent protection for these conductors shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum and copper-clad aluminum.

* For dry locations only. See 75°C column for wet locations.

13

Image 13
Contents Statesmantm Electric Models Recovery Capacity DimensionsForeword Table of ContentsApprovals Model & Rating Plate Getting to Know Your Water Heater Installation General Safety InformationRelief Devices Temperature Limiting ControlHydrogen GAS Flammable ONE or TWO Temperature ONE Heater Piping DiagramONE or TWO Temperature TWO Heater ONE or TWO Temperature Four Heaters ONE or TWO Temperature Three HeatersMedium Temperature ONE Heater Horizontal Storage Tank Medium Temperature ONE Heater Vertical Storage TankMedium Temperature TWO Heaters Horizontal Storage Tank Medium Temperature TWO Heaters Vertical Storage TankMedium Temperature Three Heaters Horizontal Storage Tank Medium Temperature Three Heaters Vertical Storage TankInstall in Accordance with ALL Local Codes Branch Circuit ElectricalHeater Circuits Wiring Diagrams Power CircuitAmperage TABLE/OVERCURRENT Protection Control CircuitSmall Commercial Wire Diagram Small Commercial Wire Diagram Single Phase Phase Conversions300-600V / 3PH Operation Temperature RegulationFilling Start UPDraining MaintenanceFlushing Sediment RemovalNot enough or no hot water ChecklistIf YOU Cannot Identify or Correct the Source of Malfunction Anode MaintenanceLeakage Checkpoints Model SSE Limited Warranty Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

SSE-120, SSE-5 specifications

State Industries has long been a trusted name in the manufacturing of water heating solutions, and their SSE series exemplifies this commitment to quality and innovation. The SSE-120 and SSE-5 models are two standout products in their lineup, catering to diverse needs in both residential and commercial applications.

The SSE-120 is a remarkable electric water heater designed with efficiency and performance in mind. It boasts a substantial 120-gallon capacity, making it ideal for larger households or small businesses with significant hot water demands. This model features a robust stainless steel tank, which not only enhances its durability but also provides excellent insulation to minimize heat loss. A key technology incorporated in the SSE-120 is its advanced dual heating element system, which ensures rapid water heating and consistent temperature maintenance, catering to high volume usage without compromising performance.

On the other hand, the SSE-5 is tailored for locations where space is a premium but hot water needs are still considerable. This model has a 5-gallon capacity and is perfect for point-of-use applications, such as supplying sinks, showers, or small appliances. The SSE-5 is designed with a tank-style configuration that guarantees a steady supply of hot water whenever needed. Its compact structure makes it easy to install in various settings, including under sinks or in cramped utility rooms.

Both models utilize a high-quality, energy-efficient design that complies with modern energy standards, helping users minimize utility bills while reducing their carbon footprint. The tanks in the SSE series are insulated with high-density foam, which not only helps in energy conservation but also ensures that users receive hot water quickly and efficiently.

Another noteworthy characteristic of the SSE series is their user-friendly controls. With adjustable temperature settings, both the SSE-120 and SSE-5 allow users to customize water temperatures according to specific needs, enhancing user experience and convenience.

In conclusion, State Industries' SSE-120 and SSE-5 water heaters combine advanced technology, superior construction, and energy efficiency, making them excellent choices for anyone in need of reliable hot water solutions. Whether for home or business, these models are built to meet the diverse demands of users in today’s water heating market.