State Industries SSE-120, SSE-5 warranty General Safety Information, Installation

Page 5

GENERAL SAFETY

INFORMATION

INSULATION BLANKETS

Insulation blankets available to the general public for external use on electric water heaters are not approved for use on your State water heater. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank water heaters. Your State water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can result in fire, asphyxiation, serious personal injury or death.

1.DO NOT COVER THE JUNCTION BOX EXTERNAL WIRING, THERMOSTATS OR HEATING ELEMENTS ON ELECTRIC WATER HEATER.

2.DO NOT COVER THE TEMPERATURE-PRESSURE RELIEF VALVE.

3.DO NOT COVER OPERATING INSTRUCTIONS, INSTALLATION OR SAFETY RELATED LABELS.

4.DO OBTAIN NEW WARNING AND INSTRUCTION LABELS FROM STATE WATER HEATERS FOR PLACEMENT ON THE BLANKET DIRECTLY OVER THE EXISTING LABELS.

5.WATER AND/OR CONDENSATE CAN COLLECT IN AN INSULATION BLANKET. STATE WATER HEATERS WILL NOT BE LIABLE FOR ANY RUST OR CORROSION DAMAGE CAUSED BY THE INSTALLATION OF INSULATION BLANKETS.

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

EXTERNAL DAMAGE

Do not operate the water heater until it has been fully checked out by a qualified service technician, if the water heater:

Has been exposed to fire or damage.

Produces steam or unusually hot water.

If the water heater has been subject to flooding, it must be replaced.

INSTALLATION

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND ELECTRICAL WORK INVOLVED.

GENERAL

The installation must conform to these instructions and the local code authority having jurisdiction. Grounding and electrical wiring connected to the water heater must also conform to the latest version of the NATIONAL ELECTRICAL CODE and NFPA-70. Copies of these codes may be obtained from American National Standards Institute, 1430 Broadway, New York, NY 10018.

If your location requires the installation of the water heater to comply with National Sanitation Foundation requirements, the heater must be sealed to the floor so as to prevent seepage underneath the heater. The following are recommended sealants that may be used on all types of flooring except concrete: GE Silicone Seal RTV-120, 103, 108 and 109.

DO NOT TEST ELECTRICAL SYSTEM BEFORE HEATER IS FILLED WITH WATER, FOLLOW START UP PROCEDURE AS WRITTEN IN “OPERATION” SECTION OF THIS MANUAL.

The principal components of the heater are identified in figure 1. The model and rating plate on page 3 interprets certain markings into useful information. Both of these references should be used to identify the heater, its components and optional equipment.

LOCATION

For proper installation, the heater should be installed on a level surface.

LOCATE IT NEAR A FLOOR DRAIN. THE HEATER SHOULD BE LOCATED IN AN AREA WHERE LEAKAGE FROM THE HEATER OR CONNECTIONS WILL NOT RESULT IN DAMAGE TO THE ADJACENT AREA OR TO LOWER FLOORS OF THE STRUCTURE.

WHEN SUCH LOCATIONS CANNOT BE AVOIDED, A SUITABLE DRAIN PAN SHOULD BE INSTALLED UNDER THE HEATER. Such pans should be fabricated with sides at least 2” (50.8 mm) deep, with length and width at least 2” (50.8 mm) greater than the diameter of the heater and must be piped to an adequate drain. Drain pans suitable for these heaters are available from your distributor or State Water Heaters, 500 Lindahl Parkway, Ashland City, TN 37015.

Locate the heater close to the point of major hot water usage and the power supply.

Try to make hot water piping and branch circuit wiring as short as possible.

Insulate hot and cold water piping where heat loss and condensation may be a problem.

THE HEATER SHOULD NOT BE LOCATED IN AN AREA WHERE IT WILL BE SUBJECT TO FREEZING.

Suggested clearances from adjacent surfaces are 18 inches (457.2 mm) in front for access to the controls and elements and 12 inches (304.8 mm) from top. The heater may be installed on or against combustible surfaces.

CONNECTIONS

The heater water inlet is located on the side of the heater near the bottom. The heater outlet is located at the top of the heater.

Piping and wiring diagrams are included in this manual.

5

Image 5
Contents Statesmantm Electric Models Recovery Capacity DimensionsApprovals Model & Rating Plate Table of ContentsForeword Getting to Know Your Water Heater Installation General Safety InformationHydrogen GAS Flammable Temperature Limiting ControlRelief Devices ONE or TWO Temperature TWO Heater Piping DiagramONE or TWO Temperature ONE Heater ONE or TWO Temperature Four Heaters ONE or TWO Temperature Three HeatersMedium Temperature ONE Heater Horizontal Storage Tank Medium Temperature ONE Heater Vertical Storage TankMedium Temperature TWO Heaters Horizontal Storage Tank Medium Temperature TWO Heaters Vertical Storage TankMedium Temperature Three Heaters Horizontal Storage Tank Medium Temperature Three Heaters Vertical Storage TankInstall in Accordance with ALL Local Codes Branch Circuit ElectricalHeater Circuits Wiring Diagrams Power CircuitAmperage TABLE/OVERCURRENT Protection Control CircuitSmall Commercial Wire Diagram Small Commercial Wire Diagram Single Phase Phase Conversions300-600V / 3PH Operation Temperature RegulationFilling Start UPDraining MaintenanceFlushing Sediment RemovalNot enough or no hot water ChecklistIf YOU Cannot Identify or Correct the Source of Malfunction Anode MaintenanceLeakage Checkpoints Model SSE Limited Warranty Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax

SSE-120, SSE-5 specifications

State Industries has long been a trusted name in the manufacturing of water heating solutions, and their SSE series exemplifies this commitment to quality and innovation. The SSE-120 and SSE-5 models are two standout products in their lineup, catering to diverse needs in both residential and commercial applications.

The SSE-120 is a remarkable electric water heater designed with efficiency and performance in mind. It boasts a substantial 120-gallon capacity, making it ideal for larger households or small businesses with significant hot water demands. This model features a robust stainless steel tank, which not only enhances its durability but also provides excellent insulation to minimize heat loss. A key technology incorporated in the SSE-120 is its advanced dual heating element system, which ensures rapid water heating and consistent temperature maintenance, catering to high volume usage without compromising performance.

On the other hand, the SSE-5 is tailored for locations where space is a premium but hot water needs are still considerable. This model has a 5-gallon capacity and is perfect for point-of-use applications, such as supplying sinks, showers, or small appliances. The SSE-5 is designed with a tank-style configuration that guarantees a steady supply of hot water whenever needed. Its compact structure makes it easy to install in various settings, including under sinks or in cramped utility rooms.

Both models utilize a high-quality, energy-efficient design that complies with modern energy standards, helping users minimize utility bills while reducing their carbon footprint. The tanks in the SSE series are insulated with high-density foam, which not only helps in energy conservation but also ensures that users receive hot water quickly and efficiently.

Another noteworthy characteristic of the SSE series is their user-friendly controls. With adjustable temperature settings, both the SSE-120 and SSE-5 allow users to customize water temperatures according to specific needs, enhancing user experience and convenience.

In conclusion, State Industries' SSE-120 and SSE-5 water heaters combine advanced technology, superior construction, and energy efficiency, making them excellent choices for anyone in need of reliable hot water solutions. Whether for home or business, these models are built to meet the diverse demands of users in today’s water heating market.