TABLE 3 - CONTROL SYSTEM MENUS

 

 

MENUS

DESCRIPTION

Temperatures

Most commonly accessed menu. Operating Set Point, Differential settings, Tank Temperature and Tank Probe

Offset are located in this menu.

 

 

 

Heater Status

Current Operating State/Mode (heating/standby etc) and status (open/closed - on/off - yes/no) of monitored

water heater functions and components are displayed in this menu.

 

 

 

Economy Mode Setup

Seven day 24 hour time clock with temperature set back capability to reduce operating costs during unoccupied

or reduced demand periods.

 

 

 

 

The control system’s CCB (Central Control Board - see wiring diagrams) features on board SPDT (single pole

Alarm Output Setup

double throw) relay contacts for building EMS (Energy Management System) notification of operational conditions

such as Fault Conditions and heating mode status. This menu features a list of user definable conditions for

 

 

relay activation.

Display Settings

Temperature units (°F or °C), appearance (brightness contrast) and backlight delay user adjustable settings are

located in this menu.

 

 

 

Heater Information

Elapsed time of operation, total heating cycle time, heating cycle count, heating element(s) cycle count and on

time along with UIM and CCB software revisions can be viewed in this menu.

 

 

 

Current Fault/Alert

Displays any current Alert or Fault messages.

 

 

 

Retains 9 event history of Fault/Alert messages with time stamp. The Fault History is useful when dealing with

Fault History

intermittent operational problems or when the customer has reset the control system prior to a service agent’s

 

arrival.

 

 

 

Total accumulated number each individual Fault condition has occurred is displayed in this menu. This

Fault Occurrence

running total of Fault Occurrences can be useful in determining which (if any) operational problems have been

 

persistent.

 

 

Restore Factory Defaults

This control system feature allows the user to restore control system user settings to their factory default settings.

Alarm Output Setup and Display Settings menu items ARE NOT changed when factory defaults are restored.

 

 

 

Accessible by pressing the corresponding Operational Button from most menus and screen displays. This menu

Help Menu

provides access to instructions and explanations for user settings, Operating States, Status Icons, manufacturer’s

 

web address, technical support phone number and service agent contact information.

 

 

11

Image 11
Contents Commercial Electric Water Heater Safe INSTALLATION, USE and Service Grounding Instructions General Safety InformationPrecautions Hydrogen GAS Flammable Introduction Table of ContentsElectrical Data ECO Temp Wiring DiagramsThermostat Controls Temperature RegulationHigh Temperature Limit Controls ECO Mixing Valves Temperature Adjustment Control System Navigation Control System FeaturesControl System Operation Heating Element OperationOperating States Status Icons DescriptionMenus Description Control System MenusTemperatures Menu Action Temperature SettingsWater Heater Status Menu Economy Mode Setup MenuCurrent Time Heater In Economy ModeDaily Operating Mode Sun Mon Tue Wed Thu Fri Sat Setpoint Adjustment Value Economy Mode SettingsTime Clock Settings Normal Operation Between Daily Operating Mode SettingsEconomy Mode All Day Heater Information Menu Alarm Output Setup MenuDisplay Settings Menu Fault Occurrence Menu Current Fault / Alert MenuFault History Menu Factory Defaults Restore Factory Defaults Restore Factory Defaults MenuWater Heater Makes Strange Sounds Troubleshooting ChecklistNot Enough or No Hot Water Water Is Too Hot