Connecting the Dual T1 Lines

Table 5-2:50-Pin Tip & Ring Jack

Pair

Pin Location

 

Function

 

26

 

Tip Channel 1

1

1

 

Ring Channel 1

 

 

 

 

 

27

 

Tip Channel 2

2

2

 

Ring Channel 2

 

 

 

 

 

 

 

 

 

 

49

 

Tip Channel 24

24

24

 

Ring Channel 24

 

 

 

 

 

50

 

Alarm Tip Channel 25

25

25

 

Alarm Ring Channel 25

 

 

 

 

5.5 Connecting the Dual T1 Lines

5.5.1 Customer Premises Installations

Connections to the T1 network interfaces are made at the RJ-48C 8-pin modular jacks on the Access Bank II SNMP Control Panel (see Figure 5-1) using one (or two) 10-foot Category 5 T1 cable(s).

Note: Only one T1 network interface cable is provided with each unit. Additional cables (P/N 005-0009) are available from distributors or dealers of CAC products.

The pin assignments for the RJ-48C jacks are defined in Table 5-3.

Table 5-3: T1 Line Interface on RJ-48C—T1 Modular 8-Pin Jack

Pin Number

Signal

Signal Direction

1

Receive Ring

From DS1 Network

2

Receive Tip

From DS1 Network

3

No connection

 

 

 

 

4

Transmit Ring

To DS1 Network

 

 

 

5

Transmit Tip

To DS1 Network

6

No connection

 

 

 

 

7

Receive Ground

 

 

 

 

8

Transmit Ground

 

For a customer premise installation, the primary T1 Span 1 and secondary T1 Span 2 network inter- faces are cabled to carrier T1 demarcation points on the customer premises. To connect these cables, plug either end into the RJ-48C connector of the desired T1 network interface and the other end into the RJ-48C jack at the carrier T1 demarcation point jack.

9/24/01

5-5

Page 52
Image 52
Carrier Access SNMP manual Connecting the Dual T1 Lines, Customer Premises Installations