Configuring the Access Bank

8. Check the configuration of T1 port #1:

Access Bank II> ds1 1

- DS1 d1

 

 

ds1 d1

circuitid

"T1 Circuit AD456-7Y"

ds1 d1

csu

on

ds1 d1

lbo

dsx0csu0

ds1 d1

linetype

d4

ds1 d1

linecode

b8zs

ds1 d1

prm

att

To change the framing and then check the configuration:

Access Bank II> ds1 1 linetype esf

Access Bank II> ds1 1

- DS1 d1

 

 

ds1 d1

circuitid

"T1 Circuit AD456-7Y"

ds1 d1

csu

on

ds1 d1

lbo

dsx0csu0

ds1 d1

linetype

esf

ds1 d1

linecode

b8zs

ds1 d1

prm

att

To remove all the connections between T1, Analog, and V.35 ports:

Access Bank II> kill d1

Access Bank II> kill d2

To set the connections (example is channels 1-12 of T1 #1 to V.35 port, channels 13-24 of T1 #1 to FXS card in first analog slot):

Access Bank II> make v1 d1:1 12

Access Bank II> make d1:13 f1:1 12

Access Bank II> connections

1)Span d1: "T1 Circuit AD456-7Y"

v1:01 v1:02 v1:03 v1:04 v1:05 v1:06 v1:07 v1:08 v1:09 v1:10 v1:11 v1:12 f1:01 f1:02 f1:03 f1:04 f1:05 f1:06 f1:07 f1:08 f1:09 f1:10 f1:11 f1:12

2)Span d2: "T1 Port #2 - Not in Service"

9/24/01

6-5

Page 66
Image 66