LED Test and Status Indicators

SNMP Control Panel. Setting this switch to the Alarm Cut-Off position (ON) opens the alarm relay contacts (150 Vrms, 150 mA maximum load) that close when the Access Bank II - SNMP enters an alarm state.

Table 9-3 defines the pin functions on the 50-pin Tip & Ring jack.

Table 12-3: 50-Pin Tip & Ring Jack

Pin Location

Function

26

Tip Channel 1

1

Ring Channel 1

 

 

27

Tip Channel 2

2

Ring Channel 2

 

 

 

 

49

Tip Channel 24

24

Ring Channel 24

 

 

50

Alarm Tip Channel 25

25

Alarm Ring Channel 25

12.11 LED Test and Status Indicators

Five test and status LED indicators on the Access Bank II - SNMP Control Panel provide a visual means of identifying system, T1 line and V.35 interface troubles.

Table 12-4: T1 Line Status LEDs for T1 Span 1 and T1Span 2

State

Meaning

OFF

Loss of T1 signal, no pulses received.

GREEN

Access Bank II - SNMP is in frame

 

with a frame-bit error rate <10E-5.

 

 

FLASHING GREEN

Access Bank II - SNMP is in frame,

 

but frame-bit error rate exceeds 10E-

 

5.

 

 

RED

AIS (Unframed All Ones Signal)

 

received from the incoming T1 span.

 

 

FLASHING RED

Access Bank II - SNMP is not syn-

 

chronized to the incoming T1 line,

 

but no AIS is being received.

 

 

YELLOW

BPV errors received on the T1 line

 

that are not due to B8ZS line coding.

 

 

FLASHING YELLOW

Yellow Alarm received from the T1

 

line.

 

 

9/24/01

12-13

Page 134
Image 134
Carrier Access SNMP manual Pin Tip & Ring Jack, T1 Line Status LEDs for T1 Span 1 and T1Span