defined signaling options.)

DC Loop Range: 1200 ohms (3 miles on 24 AWG + 300 ohms telephone)

Loop Feed: Nominal -48 Vdc with 30 mA current limit

Separate Transmit/Receive Gain Settings on a Per Channel Basis

All-channel simultaneous ringing power: 85 Vrms at 20 Hz

Built-in ringback tones

Battery Reversal FXS/DPO Voice Card

FXS Loop Start with Battery Reversal or Dial Pulse Originating (DPO) functionality per card

Optional Cadenced Ringback Tone (two-seconds on, four seconds off) to the T1 line dur- ing incoming calls, synchronized to the ringing voltage present on the loop

Optional Cadenced Ringing Voltage applied to CPE loop during an incoming call

Supports CLASS® services, including Caller ID

3.11FXO/DPT Voice Card

FXO Loop-Start/Ground-Start terminations per channel

Dial Pulse Termination (DPT) functionality per card

Separate transmit and receive gain settings per channel

DID and DNIS carrier services

CLASS® services, including distinctive ringing and caller ID

3.124-Wire E&M/TO Voice Card

Optioned with on-board jumpers to support E&M signaling types I, II, IV, or V, for each channel

Supports Transmission Only (TO) for dedicated modems, radio/paging systems, etc.

Separate gain and loss settings from +10 dB to -21 dB for both transmit and receive paths for each channel

Maximum analog transmission level of +9.5 dBm

3.13Network Management

RS-232 Primary Management Port, Cable, Command Line Interface, and MS Windows- based Remote Monitor Graphical User Interface (GUI) software program included with

3-4

9/24/01

Page 33
Image 33
Carrier Access SNMP manual 11 FXO/DPT Voice Card, 12 4-Wire E&M/TO Voice Card, Network Management