12-Channel FXO & Dial Pulse Termination Card

detect battery reversal from the PBX for call progress and confirmation of call comple- tion.

10.3.3Channel Attenuation Options

Each of the 12 channels can be configured to attenuate both the transmit and receive audio signal. Each channel has a 6-position dip switch; three positions for transmit attenuation and three positions for receive attenuation. The switch positions apply different values of attenuation, and are additive (if more than one switch is set to apply attenuation for a specific channel, the attenuation value for the channel is the sum of those switches).

The loss is measured in decibels (dB). Note that a 3dB loss implies the average power is reduced by 50%.

The following table shows the values of attenuation applied for each switch position.

Note: Attenuation is applied when the switch is in the OFF position, and is removed when the switch is in the ON position.

Table 10-2: Transmit and Receive Attenuation Switch Values

Switch

Transmit Switch Position Loss

Receive Switch Position Loss

Setting

1

2

3

4

5

6

 

 

 

 

 

 

 

On

0 dB

0 dB

0 dB

0 dB

0 dB

0 dB

Off

-2 dB

-3 dB

-4 dB

-2 dB

-3 dB

-4 dB

 

 

 

 

 

 

 

Caution: Use proper electrostatic discharge (ESD) procedures when handling the analog cards.

10-4

9/24/01

Page 101
Image 101
Carrier Access SNMP manual Channel Attenuation Options, Transmit and Receive Attenuation Switch Values