V.35 DCE Data Port Connections
9/24/01 5-7
This cable is used to connect the Access Bank II SNMP V.35 DCE data port (Figure 5-3) to synchro-
nous V.35 DTE data sources up to 1.536 Mbps, all rates (1-24) Nx56 or Nx64 channel-rate progres-
sion. The CAC V.35 Data Cables are built accor ding t o the pin as signment s li sted be low in Table 5-5.
Figure 5-4 shows the pin layout of the standard 34-pin V.35 Winchester connector typically used to
connect to Routers and FRADs.
To connect the CAC V.35 data cable to the V.35 DCE data port, connect the end with the 26-pin
micro-D male connector to the Access Bank II SNMP V.35 DCE data port and the end with the 34-
pin Winchester male connector to the V.35 DTE data source.
Table 5-5: Pin Assignments for CAC V.35 Data Cables
Micro-D
26-pin (male) Signal Winchest er
34-pin (male) Paired
Signals
1 (+ Shield) Protective Ground Aù
7 Signal Ground Bû
2 Transmit Data A Pù
14 Transmit Data B Sû
3 Receive Data A Rù
16 Receive Data B Tû
4 RTS Cù
20 DTR Hû
5 CTS Dù
6 DSR Eû
12 Test M ode Kù
8 CD (RLSD) Fû
11 External Clock A Uù
24 External Clock B Wû
10 Xmit Clock A Yù
23 Xmit Clock B AA û
15 Receive Clock A Vù
17 Receive Clock B Xû
22 Local Loopback Jù
25 Remote Loopback BB û
9, 13, 18 Open Pins/No Contact L, N, NN
19, 21, 26 Open Pins/No Contact