Snmp
Page
 FCC Requirements
 Safety Requirements
 Warranty
 Warranty Product Returns
Page
 Contents Access Bank II Snmp
 Chapter Physical Installation
Chapter Electrical Installation
 Chapter Initialization Basic Configuration
Remote Monitor
 Chapter FXS-ID Configuration
Chapter Battery Reversal FXS & Dial Pulse Origination Card
 Chapter Wire E&M/TO Configuration
Chapter Channel FXO & Dial Pulse Termination Card
 Chapter Diagnostics Troubleshooting
Xvi
 Chapter Maintenance
Chapter Snmp Management & Command Line Interface
 Xviii
 Xix
Page
 About This Chapter
General System Overview
 Dual T1/CSU Network Interfaces
Features, Functions, and Options
Standard Features
Software Programmable Functions
 1 V.35 DCE Port
Analog Line Interfaces FXS, & FXO, and 4-Wire E&M
Digital Data Ports
2 RS-232 Data Port
 Local/Remote Mode Selection
Local and Remote Network Management
 Snmp Management
Local and Remote Snmp Management
Snmp Overview
 Command Line Interface
Local and Remote CLI Management
 Windows-Based GUI Management Software
Local and Remote Telnet CLI Management
 Design Philosophy
Local and Remote GUI Management
 Physical Characteristics
Product Description
 Control Panel Interface Connectors
 Control Panel DIP Switches
LED Test and Status Indicators
 Access Bank II Snmp Top Cover Installation Guide
 Technical Specifications
 Dual T1 Network Line Interfaces
T1-to-T1 Delay
T1 Channel Service Units CSUs
Line Codes
 1 V.35 Serial Port
Analog Line Interfaces
FXS Voice Card
2 RS-232 Remote Management/Data Port
 12 4-Wire E&M/TO Voice Card
11 FXO/DPT Voice Card
Network Management
 Alarms
Control Panel I/O Connectors
Standards Compliance
 Power
Physical Dimensions
Environmental
 Installation
 24/01
 Physical Installation
Installation Check List
 Access Bank II Snmp Packing Materials List
Description
 Chassis Mounting
 Wall Mounting
Rack Mounting
 Surface Mounting
Rack Mounting with Brackets Shipped with Unit
Mounting with Heavy-Duty Brackets
 Mounting the Power Converter
Wall-Mounting the Access Bank II Snmp
 2Rack Mounting on a 19 Rack Using Small Brackets
 Rack Mounting on a 19 Rack Using Heavy-Duty Brackets
 4Optional Heavy Duty Brackets
 24/01
 Electrical Installation
 Installing Cables and Adapters
DCE-MF
 DC Power Connector Input
Snmp Connector
3 V.35 DCE Data Port Connector
1 RJ-48C Jacks for T1 Span 1 and Span
 Connecting the Voice Circuits
Tip & Ring Jack female
 Connecting the Dual T1 Lines
Customer Premises Installations
T1 Line Interface on RJ-48C-T1 Modular 8-Pin Jack
 V.35 DCE Data Port Connections
Abam 600 T1 Cable
3 24 AWG Twisted-Pair
 Micro-D Signal Winchester Paired Pin male Signals + Shield
Pin Assignments for CAC V.35 Data Cables
 Access Bank II Snmp V.35 DCE Data Port Connections
 Access Bank II Snmp V.35 DCE Port female
 RS-232 Management
1 RS-232 DCE Management Cable Local Management Cable
 Null Modem Adapter
CAC Local Management Adapter Cable Pin Assignments
 Straight Adapter
7Null Modem Adapter Pin Assignments
 Connecting the Power and Ground
Power Connector Pinout Assignments
CAC Straight Adapter Pin Assignments
 24/01
 Initialization Basic Configuration
Connecting to the Access Bank
 Configuring the Access Bank
AB-II Snmp in an Example Network
 Check the system clocking configuration
 Check the time information
 Check the configuration of T1 port #1
 To set Snmp configurations, if required examples given below
 Nicholas Jones, 203-555-8897, PIN #33345
 24/01
 Remote Monitor
 Remote Monitor Software Program
Message Traffic
Overview
 Online Help
Hardware Requirements
 Initialization for Basic Operation in the Remote Mode
Remote Monitor Screen Hierarchy
 FXS-ID Configuration
FXS-ID Voice Card
 Signaling Types
FXO Switch to AB2 FXS A/B Signaling
Wink-Start to Loop-Start or Ground-Start
 Setting the FXS Transmit and Receive Levels
Wink Delay
 FXS Transmit and Receive Level Option Settings
 FXS Signaling Summary
Option Switch Signaling Number
 Setting the FXS Signaling Options
Option Switches A, B, and C
 FXS Signaling Option Descriptions
FXS Signaling Options
 Option 2. Wink-Start to Ground-Start Conversion
Option 3. E&M Immediate-Start-to-Loop-Start Conversion
Option 4. E&M Immediate-Start-to-Ground-Start Conversion
 Option 7. Customized Signaling
 FXS Voice Channel Monitoring and Testing
TP Busy/Idle Switch
 FXS Backplate Switches
FXS Backplate LEDs
 Busying Out Individual FXS Channels
Self Test Loopbacks
 FXS Voice Channel Monitoring and Testing
 24/01
 Battery Reversal FXS & Dial Pulse Origination Card
Description of the BRFXS/DPO Card
 Overview of Operation
 BRFXS/DPO Applications
DPO
 Setting the Transmit and Receive Levels
Transmit and Receive Attenuation Switch Values
 Brfxs V
 BRFXS/DPO Configuration Settings
OFF
 BRFXS/DPO Back Plate LEDs
 BRFXS/DPO Voice Channel Monitoring and Testing
Setting Brfxs and DPO
Battery Reversal FXS Loop-Start
Busying Out Individual BRFXS/DPO Channels
 Self Test Loopbacks
 24/01
 Channel FXO & Dial Pulse Termination Card
Description of the FXO Card
 Termination Options and Switch Settings for the FXO/DPT
Termination Options
Foreign Exchange Office FXO Termination
 Dial Pulse Termination DPT
Termination Options
 Channel Attenuation Options
 FXO V
 10-6
 11.2 4-Wire E&M/TO Voice Card
Functional Description
 Typical Applications
Physical Description
 11.4 E&M Signaling Conventions
Signaling Conventions
 Detector-Driver Functions
48V
 5E&M Signaling Type
 Programming E&M Signaling Types
Jumper Switch Settings
Jumper Connections by Type and Mode
 Detector Configuration
4-Wire E&M Signaling Options
 Normal and Tandem Mode Cables for 4-wire E&M/TO Card
Configuring Signaling Types and Trunk Processing
E&M T1 Signaling
Normal and Tandem Cables
 4-Position DIP Switch Settings
TP Busy/Idle Switch
Setting Transmit and Receive Gain
Transmit Analog-to-Digital Gain
 Receive Digital-to-Analog Gain
11.14 E&M Normal mode cable
Call Progress LED Indicators
11.13 E&M Voice Channel Monitoring
 Cable Type
Common Connector
Telco Connectors
Markings
 11.15 E&M Tandem Mode Cable
E&M Normal Mode Cable
 E&M Tandem Mode Cable
 7Part 1 Connector Pinouts for Cable P/N
Normal Mode Telco Connector a Telco Connector B
 Part 2 Connector Pinouts for Cable P/N
 Part 1 Connector Pinouts for Cable P/N
 11-17
 11-18
 Diagnostics Troubleshooting
Diagnostic Switches
 Local Mode OFF = No Test Tone, on = Ringback Tone
Self Test 1
 Card Self Test
Self Test Fault Indications
Card Self Test Signaling States
Voice Channel LED is RED during Self Test
 Local Mode No Network Loopback or Network Loopback Enabled
12.5 1 kHz Digital Milliwatt Test Signal
Remote Mode Ringback Tone or 1 Digital Milliwatt
Standard Digital Milliwatt Signal
 Illustrations of Loops and Self-Tests
Remote Mode Remote T1 Line or Payload Loopbacks
Ansi T1.403 Remote T1 LLB
Ansi T1.403 Remote Payload Loopback
 Self-Test
Loopback Legend
 Equipment Loopback
Equipment Loopback Payload
 12.9.4 DS-1 Network Loopback
DS-1 Network Loopback Payload
 Receiving DS-1 CSU Loopback
Sending DS-1 CSU Loopback
 Sending DS-1 Bert Pattern
12.9.9 V.35 Equipment Loopback
 12.9.10 V.35 Network Loopback
Sending V.54 Loopback
 Disabling an External Alarm
Receiving V.54 Loopback
Sending FX Ring or Tone
 50-Pin Tip & Ring Jack
T1 Line Status LEDs for T1 Span 1 and T1Span
 Fault Isolation Procedures
T1 Test LEDs for T1 Span 1
V.35 Status LED
 Control Panel LED Indications
 Voice Channel LED is RED during a Self Test
Other Fault Indications
Back Plate Indications
All Voice Channel LEDs flash RED
 Access Bank II Snmp Shuts Down for No Apparent Reason
 12-18
 Maintenance
 Replacing a Voice Card
 Accessing the Voice Cards
Replacing the Controller Card
 Removing the Chassis Tray
 Replacing the Controller Card
 13-6
 Snmp Management Command Line Interface
Local/Remote Mode Selection
 Snmp Management
Local and Remote Snmp Management
Snmp Overview
 Protocol Hierarchy Used In Access Bank II Snmp
Protocols
 Statistics
Commands
Management Information Bases
Supported Management Information Bases
 Traps
 Command Line Interface CLI
Maintenance
Local and Remote CLI Management
 Command Line Interface CLI
14.4.2 RS-232 CLI Operation
 Context Sensitive Help
 Context sensitive help, type ? at any time
 CommandLineInterfaceHelp.Forimmediate
 Code ipaddr path .Load app code path from Tftp server
 DPT
 DSX
 Ring
 Disable any Current Loopback General Loopback Usage
 Display/Set Optional Data RS-232 Port
 Echo Echo Telnet output on serial line Off Disable Enable
 Configuration Commands
14.4.4.1 aco
 Alarms
Boot
14.4.4.3 aps
 Config
14.4.4.5 clk
Connections
 Craft
Date
 14.4.4.10dni
14.4.4.11dialout
14.4.4.12 ds1
 Event
Exit
14.4.4.15 ip
 14.4.4.18 mac
Kill
Loop
Make
 Password
Name
Ping
 Snmp
14.4.4.23 rs232
Screen height
Telnet
 Trap
 Status Commands
14.4.4.30
14.4.5.1equipment
 14.4.5.2 log
Statistics
Status
 14-30
 Glossary
 Channel Service Unit See DSU/CSU
 ESF Extended Superframe Format
 PBX Private Branch Exchange Performance Report Message PRM
 Trunk Processing TP