14.4.4.30 v35

Use the v35 command to configure parameters for the V.35 data port to be accessed by the SNMP manager via RFC-1659.

Operations

Type

Comments

 

 

 

To set the circuit ID to

v35 circuitid “V.35 - 1”

Sets the Circuit Id for the V.35 port

“V.35 - 1”

 

 

 

 

 

To set clock inversion to

v35 clkinv rx

Sets the receive clock to be inverted.

receive clock inverted

 

 

 

 

 

To set CTS to follow

v35 cts rts

Sets CTS to follow RTS signal

RTS signal

 

 

 

 

 

To set data inversion

v35datainv invert

Sets the V.35 data to be inverted.

 

 

 

To set receive clock

v35 rxclk internal

Sets thte system to use the Internal

source to be internal

 

Clock.

 

 

 

To set the speed to be

v35 speed nx56

Sets the data raste to Nx56 KBps

nx56

 

 

 

 

 

To display Help

v35 ?

 

 

 

 

 

 

 

14.4.5 Status Commands

14.4.5.1equipment

Use the equipment command to display the hardware equipment configuration within the Access Bank.

Operations

Type

Comments

 

 

 

To display the equipment

equipment

Displays a list of the current installed

list

 

hardware and Firmware revision

 

 

levels.

 

 

 

 

 

 

14-28

9/24/01

Page 173
Image 173