14-28 9/24/01

14.4.4.30 v35

Use the v35 command to configure parameters for the V.35 data port to be accessed by the SNMP
manager via RFC-1659.
14.4.5 Status Commands

14.4.5.1equipment

Use the equipment command to display the hardware equipment configuration within the Access
Bank.
Operations Type Comments
To set the circuit ID to
“V.35 - 1” v35 circuitid “V.35 - 1” Sets the Circuit Id for the V.35 port
To set clock inversion to
receive clock inverted v35 clkinv rx Sets the receive clock to be inverted.
To set CTS to follow
RTS sig nal v35 cts rts Sets CTS to follow RTS signal
To set data inversion v35datainv invert Sets the V.35 data to be inverted.
To set receive clock
source to be internal v 35 rxclk internal Sets thte system to use the Internal
Clock.
To set the speed to be
nx56 v35 speed nx56 Sets the data raste to Nx56 KBps
To display Help v35 ?
Operations Type Comments
To display the equipment
list equipment Displays a list of the current installed
hardware and Firmware revision
levels.