4.7 Mounting the Power Converter

The Access Bank II - SNMP is normally shipped for US operation with a 115 Vac to -48 Vdc power conversion cube. This cube includes both a 5-foot grounded AC power cord and a 8-foot three-posi- tion DC power cable. The Power Converter Cube has four mounting holes for attaching the unit to a wall or other flat surface. To mount the Power Converter Cube on a nearby wall, locate the converter within 7 feet of the Access Bank II - SNMP front Control Panel and use screws or anchors appropri- ate to the mounting surface. If you are wall mounting the power conversion cube on the same ¾” thick plywood sheet as the Access Bank II - SNMP, the dimensions of the board will have to be at least 25” by 14”. Wire tie-downs can be used to keep stray wires to a minimum, but be careful not to damage the wiring in any way.

Figure 4-1: Wall-Mounting the Access Bank II - SNMP