Access Bank II - SNMP Shuts Down for No Apparent Reason
9/24/01 12-17
1. Check the voice cable for a loose connection.
2. Check the voice cable for a broken/open pair.
3. Use Remote Monitor software to run a Self Test Loopback with the Ringback tone. If no
ringing tone is heard at the drop, the ringback generator on the Contro ller card may be f ault y.
Replace the Controller card using the procedure given in the Maintenance section.
12.15 Access Bank II - SNMP Shuts Down for No Apparent
Reason
Internal thermal protectors automatically shut down Access Bank II - SNMP operation if the operat-
ing temperature rises above 140º F (60º C). To correct this problem:
Verify that the Access Bank II - SNMP is properly ventila ted to allo w for heat diss ipation, an d reduce
the ambient temperature if necessary. The Access Bank II - SNMP resets automatically when the
temperature is reduced below 104º F (40 C).