12.9.12 Receiving V.54 Loopback

Voice

Channels

V.35

Data

V.54 Loop Up

 

Code

V.35 Data

 

Application or

DS-1 Network

BER Tester

Receiving V.54 Loop

Remote unit or network sends V.54 loop up code, loop

occurs at local data port.

Check for errors on remote data port, without BERT.

Figure 12-12: Receiving V.54 Loop

12.9.13 Sending FX Ring or Tone

Ringing or

1004 Hz Tone

Voice

Channels

DS-1 Network

V.35

Data

Sending FX Ring or Tone

Sends ringing voltage or a 1004 Hz test tone to

all the analog voice channels connected to a

specific DS-1.

Commands: ds1 d1 send equipment ring

(or) ds1 d1 send equipment tone

(1004 Hz)

ds1 d1 send equipment off

Figure 12-13: Sending FX Ring or Tone

12.10 Disabling an External Alarm

The 4-position System Setup DIP switch contains a switch labeled Alarm Cut-Off that allows you to disable an external alarm connected to pair 25 of the 50-pin Tip & Ring jack on the Access Bank II -

12-12

9/24/01

Page 133
Image 133
Carrier Access SNMP manual Disabling an External Alarm, Receiving V.54 Loopback, Sending FX Ring or Tone