T1 Test 1 or 2 LED is RED.

If the T1 Test LEDs remain red for more than

 

16 seconds after a Self Test is initiated, the

 

Access Bank II - SNMP has failed the Self Test.

 

To correct the problem:

 

1 Verify that the Controller card and at least

 

one voice card are in place.

 

2 Power down the Access Bank II - SNMP for

 

60 seconds, power it up again, and repeat the

 

Self Test.

 

3 If the Access Bank II - SNMP fails the Self

 

Test again, replace the Controller card using the

 

procedure given in the Maintenance section.

 

 

T1 Test 1 or 2 LED flashes YELLOW.

The Access Bank II - SNMP is in Network

 

Loopback. If this condition persists, the Access

 

Bank II - SNMP may not have received a loop

 

down code to end the network loopback To

 

clear this condition:

 

1 Be sure the Network Loopback switch is set

 

to OFF.

 

2 Set the Self Test switch to the Self Test ON

 

position, then back to OFF.

12.13 Back Plate Indications

12.13.1 Voice Channel LED is RED (during a Self Test)

During a Self-Test, a RED voice channel LED may appear, and does not indicate a particular prob- lem.

12.13.2 All Voice Channel LEDs flash RED

This usually indicates that an unsupported signaling option has been selected. Reconfigure the FXS card to a supported signaling type.

12.14 Other Fault Indications

12.14.1 No Ringing During a Self Test

If no ringing signal is heard at the drop for a particular channel during a Self Test, there may be an open or broken pair in the voice cable. If no ringing signal is heard on any channel during a self test, the voice cable may be disconnected. To correct the problem:

12-16

9/24/01

Page 137
Image 137
Carrier Access SNMP manual Back Plate Indications, Other Fault Indications, Voice Channel LED is RED during a Self Test