Battery Reversal FXS & Dial Pulse Origination Card

5.Press both card ejector latches in towards the FXS card to seat the 64-pin DIN connector in the matching connector on the internal Controller card.

6.Replace the back plate and tighten the thumbscrews.

9.6BRFXS/DPO Configuration Settings

The configuration of the Battery Reversal FXS/DPO card is set by a 4-position DIP switch and 12 individual channel test switches accessed through the ABI back plate. The settings for these switches are described in Table 9-2.

Table 9-2: Transmit and Receive Attenuation Switch Values

Switch

A

B

C TPIdle/Busy

Channel Test One switch per channel

Function

OFF

ON

 

 

 

Ringing Voltage

DPO Operation

2-wire FXS loop-start

 

Ringing voltage never

operation: Cadenced (2-

 

applied to CPE loop.

second/4-second)

 

 

ringing voltage applied

 

 

to CPE loop during

 

 

incoming call

Ringback Tone

Ringback tone never

Cadenced (2-second/ 4-

 

applied to network.

second) ringback tone

 

 

applied to network

 

 

during incoming call.

<Reserved>

Normal

<Reserved>

CPE loop state during

Forward battery applied

Reverse battery applied

Trunk Processing (TP)

to all CPE loops during

to all CPE loops during

 

Trunk Processing.

Trunk Processing.

Individual channel busy

Normal channel

Channel is busy - reverse

 

operation

battery applied to CPE

 

 

loop; A/B bits to

 

 

network are forced to 1/

 

 

1. In addition, if Switch

 

 

A is ON, 4 seconds of

 

 

ringing voltage is

 

 

applied to local loop,

 

 

and if Switch B is ON, 4

 

 

seconds of ringback tone

 

 

is sent toward network.

 

 

 

9-20

9/24/01

Page 93