Snmp
Page
 FCC Requirements
 Safety Requirements
 Warranty
 Warranty Product Returns
Page
 Contents Access Bank II Snmp
 Chapter Electrical Installation
Chapter Physical Installation
 Remote Monitor
Chapter Initialization Basic Configuration
 Chapter Battery Reversal FXS & Dial Pulse Origination Card
Chapter FXS-ID Configuration
 Chapter Channel FXO & Dial Pulse Termination Card
Chapter Wire E&M/TO Configuration
 Xvi
Chapter Diagnostics Troubleshooting
 Chapter Snmp Management & Command Line Interface
Chapter Maintenance
 Xviii
 Xix
Page
 General System Overview
About This Chapter
 Standard Features
Features, Functions, and Options
Dual T1/CSU Network Interfaces
Software Programmable Functions
 Digital Data Ports
Analog Line Interfaces FXS, & FXO, and 4-Wire E&M
1 V.35 DCE Port
2 RS-232 Data Port
 Local and Remote Network Management
Local/Remote Mode Selection
 Snmp Overview
Snmp Management
Local and Remote Snmp Management
 Local and Remote CLI Management
Command Line Interface
 Local and Remote Telnet CLI Management
Windows-Based GUI Management Software
 Local and Remote GUI Management
Design Philosophy
 Product Description
Physical Characteristics
 Control Panel Interface Connectors
 LED Test and Status Indicators
Control Panel DIP Switches
 Access Bank II Snmp Top Cover Installation Guide
 Technical Specifications
 T1 Channel Service Units CSUs
T1-to-T1 Delay
Dual T1 Network Line Interfaces
Line Codes
 FXS Voice Card
Analog Line Interfaces
1 V.35 Serial Port
2 RS-232 Remote Management/Data Port
 Network Management
12 4-Wire E&M/TO Voice Card
11 FXO/DPT Voice Card
 Standards Compliance
Alarms
Control Panel I/O Connectors
 Environmental
Power
Physical Dimensions
 Installation
 24/01
 Installation Check List
Physical Installation
 Description
Access Bank II Snmp Packing Materials List
 Chassis Mounting
 Rack Mounting
Wall Mounting
 Mounting with Heavy-Duty Brackets
Surface Mounting
Rack Mounting with Brackets Shipped with Unit
 Wall-Mounting the Access Bank II Snmp
Mounting the Power Converter
 2Rack Mounting on a 19 Rack Using Small Brackets
 Rack Mounting on a 19 Rack Using Heavy-Duty Brackets
 4Optional Heavy Duty Brackets
 24/01
 Electrical Installation
 DCE-MF
Installing Cables and Adapters
 3 V.35 DCE Data Port Connector
Snmp Connector
DC Power Connector Input
1 RJ-48C Jacks for T1 Span 1 and Span
 Tip & Ring Jack female
Connecting the Voice Circuits
 T1 Line Interface on RJ-48C-T1 Modular 8-Pin Jack
Connecting the Dual T1 Lines
Customer Premises Installations
 3 24 AWG Twisted-Pair
V.35 DCE Data Port Connections
Abam 600 T1 Cable
 Pin Assignments for CAC V.35 Data Cables
Micro-D Signal Winchester Paired Pin male Signals + Shield
 Access Bank II Snmp V.35 DCE Data Port Connections
 Access Bank II Snmp V.35 DCE Port female
 1 RS-232 DCE Management Cable Local Management Cable
RS-232 Management
 CAC Local Management Adapter Cable Pin Assignments
Null Modem Adapter
 7Null Modem Adapter Pin Assignments
Straight Adapter
 CAC Straight Adapter Pin Assignments
Connecting the Power and Ground
Power Connector Pinout Assignments
 24/01
 Connecting to the Access Bank
Initialization Basic Configuration
 AB-II Snmp in an Example Network
Configuring the Access Bank
 Check the system clocking configuration
 Check the time information
 Check the configuration of T1 port #1
 To set Snmp configurations, if required examples given below
 Nicholas Jones, 203-555-8897, PIN #33345
 24/01
 Remote Monitor
 Overview
Remote Monitor Software Program
Message Traffic
 Hardware Requirements
Online Help
 Remote Monitor Screen Hierarchy
Initialization for Basic Operation in the Remote Mode
 FXS-ID Voice Card
FXS-ID Configuration
 Wink-Start to Loop-Start or Ground-Start
Signaling Types
FXO Switch to AB2 FXS A/B Signaling
 Wink Delay
Setting the FXS Transmit and Receive Levels
 FXS Transmit and Receive Level Option Settings
 Option Switch Signaling Number
FXS Signaling Summary
 Option Switches A, B, and C
Setting the FXS Signaling Options
 FXS Signaling Options
FXS Signaling Option Descriptions
 Option 4. E&M Immediate-Start-to-Ground-Start Conversion
Option 2. Wink-Start to Ground-Start Conversion
Option 3. E&M Immediate-Start-to-Loop-Start Conversion
 Option 7. Customized Signaling
 TP Busy/Idle Switch
FXS Voice Channel Monitoring and Testing
 FXS Backplate LEDs
FXS Backplate Switches
 Self Test Loopbacks
Busying Out Individual FXS Channels
 FXS Voice Channel Monitoring and Testing
 24/01
 Description of the BRFXS/DPO Card
Battery Reversal FXS & Dial Pulse Origination Card
 Overview of Operation
 DPO
BRFXS/DPO Applications
 Transmit and Receive Attenuation Switch Values
Setting the Transmit and Receive Levels
 Brfxs V
 OFF
BRFXS/DPO Configuration Settings
 BRFXS/DPO Back Plate LEDs
 Battery Reversal FXS Loop-Start
Setting Brfxs and DPO
BRFXS/DPO Voice Channel Monitoring and Testing
Busying Out Individual BRFXS/DPO Channels
 Self Test Loopbacks
 24/01
 Description of the FXO Card
Channel FXO & Dial Pulse Termination Card
 Foreign Exchange Office FXO Termination
Termination Options and Switch Settings for the FXO/DPT
Termination Options
 Termination Options
Dial Pulse Termination DPT
 Channel Attenuation Options
 FXO V
 10-6
 Functional Description
11.2 4-Wire E&M/TO Voice Card
 Physical Description
Typical Applications
 Signaling Conventions
11.4 E&M Signaling Conventions
 48V
Detector-Driver Functions
 5E&M Signaling Type
 Jumper Connections by Type and Mode
Programming E&M Signaling Types
Jumper Switch Settings
 4-Wire E&M Signaling Options
Detector Configuration
 E&M T1 Signaling
Configuring Signaling Types and Trunk Processing
Normal and Tandem Mode Cables for 4-wire E&M/TO Card
Normal and Tandem Cables
 Setting Transmit and Receive Gain
TP Busy/Idle Switch
4-Position DIP Switch Settings
Transmit Analog-to-Digital Gain
 Call Progress LED Indicators
11.14 E&M Normal mode cable
Receive Digital-to-Analog Gain
11.13 E&M Voice Channel Monitoring
 Telco Connectors
Common Connector
Cable Type
Markings
 E&M Normal Mode Cable
11.15 E&M Tandem Mode Cable
 E&M Tandem Mode Cable
 Normal Mode Telco Connector a Telco Connector B
7Part 1 Connector Pinouts for Cable P/N
 Part 2 Connector Pinouts for Cable P/N
 Part 1 Connector Pinouts for Cable P/N
 11-17
 11-18
 Diagnostic Switches
Diagnostics Troubleshooting
 Self Test 1
Local Mode OFF = No Test Tone, on = Ringback Tone
 Card Self Test Signaling States
Self Test Fault Indications
Card Self Test
Voice Channel LED is RED during Self Test
 Remote Mode Ringback Tone or 1 Digital Milliwatt
12.5 1 kHz Digital Milliwatt Test Signal
Local Mode No Network Loopback or Network Loopback Enabled
Standard Digital Milliwatt Signal
 Ansi T1.403 Remote T1 LLB
Remote Mode Remote T1 Line or Payload Loopbacks
Illustrations of Loops and Self-Tests
Ansi T1.403 Remote Payload Loopback
 Loopback Legend
Self-Test
 Equipment Loopback Payload
Equipment Loopback
 DS-1 Network Loopback Payload
12.9.4 DS-1 Network Loopback
 Sending DS-1 CSU Loopback
Receiving DS-1 CSU Loopback
 12.9.9 V.35 Equipment Loopback
Sending DS-1 Bert Pattern
 Sending V.54 Loopback
12.9.10 V.35 Network Loopback
 Sending FX Ring or Tone
Disabling an External Alarm
Receiving V.54 Loopback
 T1 Line Status LEDs for T1 Span 1 and T1Span
50-Pin Tip & Ring Jack
 V.35 Status LED
Fault Isolation Procedures
T1 Test LEDs for T1 Span 1
 Control Panel LED Indications
 Back Plate Indications
Other Fault Indications
Voice Channel LED is RED during a Self Test
All Voice Channel LEDs flash RED
 Access Bank II Snmp Shuts Down for No Apparent Reason
 12-18
 Maintenance
 Replacing a Voice Card
 Replacing the Controller Card
Accessing the Voice Cards
 Removing the Chassis Tray
 Replacing the Controller Card
 13-6
 Local/Remote Mode Selection
Snmp Management Command Line Interface
 Snmp Overview
Snmp Management
Local and Remote Snmp Management
 Protocols
Protocol Hierarchy Used In Access Bank II Snmp
 Management Information Bases
Commands
Statistics
Supported Management Information Bases
 Traps
 Local and Remote CLI Management
Command Line Interface CLI
Maintenance
 14.4.2 RS-232 CLI Operation
Command Line Interface CLI
 Context Sensitive Help
 Context sensitive help, type ? at any time
 CommandLineInterfaceHelp.Forimmediate
 Code ipaddr path .Load app code path from Tftp server
 DPT
 DSX
 Ring
 Disable any Current Loopback General Loopback Usage
 Display/Set Optional Data RS-232 Port
 Echo Echo Telnet output on serial line Off Disable Enable
 14.4.4.1 aco
Configuration Commands
 14.4.4.3 aps
Alarms
Boot
 Connections
Config
14.4.4.5 clk
 Date
Craft
 14.4.4.12 ds1
14.4.4.10dni
14.4.4.11dialout
 14.4.4.15 ip
Event
Exit
 Loop
Kill
14.4.4.18 mac
Make
 Ping
Password
Name
 Screen height
14.4.4.23 rs232
Snmp
Telnet
 Trap
 14.4.5.1equipment
Status Commands
14.4.4.30
 Status
14.4.5.2 log
Statistics
 14-30
 Glossary
 Channel Service Unit See DSU/CSU
 ESF Extended Superframe Format
 PBX Private Branch Exchange Performance Report Message PRM
 Trunk Processing TP