Tip & Ring Connector

 

 

 

T1 LEDs (PER SPAN)

STATE

MEANING

OFF

Loss of T1 signal, no pulses

 

received

GREEN

Nodal Switch is in frame with

 

frame bit error rate <10E -5

FLASHING

Nodal Switch is in frame, but

GREEN

frame bit error rate exceeds 10E-5

RED

AIS (unframed all ones)

 

received from the T1 line

FLASHING

Nodal Switch is not framed to

RED

the T1 line but no AIS is received

YELLOW

Yellow alarm received from the T1 line

FLASHING

BPV errors received on the T1 line

YELLOW

that are not due to B8ZS line coding

 

 

T1 JACK

R48CPIN ASSIGNMENT

1R1 - Receive ring from T1 line

2T1 - Receive tip from T1 line

 

 

4

R - Transmit ring to T1 line

 

 

 

 

5

T - Transmit tip to T1 line

 

 

 

7&8

Ground for T1 cable shields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NODAL SWITCH CONTROL SWITCHES

 

 

SWITCH

FUNCTION

 

OFF

ON

 

 

 

SYSTEM SETUP

 

 

1

local/remote

 

local

remote

2

alarm cutoff

 

enable alarm

disable alarm

3Option 1

4Option 2

T1 SPAN 1 SETUP

1

Self test 1

off

on

2

Network loopback 1

off

on

3

T1 framing 1

Superframe

Extended

 

 

(SF) (also

superframe

 

 

called D4)

(ESF)

4

T1 line coding 1

Alternative

B8ZS

 

 

Mark

 

 

 

Inversion (AMI)

 

5

CSU on/off 1

Detect loop

Reject CSU

 

 

code (normal)

loopcode

 

T1 SPAN 2 SETUP

 

6

Self test 2

Off

On

7

Network loopback 2

Off

On

8

T1 framing 2

Superframe

Extended

 

 

(SF) (also

superframe

 

 

called D4)

(ESF)

9

T1 line coding 2

Alternative

B8ZS

 

 

Mark

 

 

 

Inversion (AMI)

 

10

CSU on/off 2

Detect loop

Reject CSU

 

 

code (normal)

loopcode

 

 

 

V.35 STATUS LED

STATE

MEANING

OFF

No T1 channels assigned to V.35

 

port

GREEN

CD and RTS active. T1 channels

 

assigned and operable

FLASHING

V.35 in loopback to equipment

GREEN

 

RED

CD is inactive because assigned

 

T1 is inoperable

YELLOW

CD active RTS inactive

FLASHING

V.35 in loopback to T1 line

YELLOW

 

 

 

 

 

 

10 BASE T ACTIVITY LED

 

 

STATE

MEANING

 

 

OFF

No data RX/TX

 

 

GREEN

RX/TX Data

 

 

RED

Collision detected

 

 

 

 

 

10 BASE T LINK LED

 

 

STATE

MEANING

 

 

OFF

No signal received

 

 

GREEN

Validate connection

 

 

 

 

 

 

 

T1 TEST LEDs (PER SPAN)

STATE

MEANING

GREEN

Normal operation. Trunk processing,

 

self test, and network loopback

 

inactive

FLASHING

T1 self test local loopback

GREEN

passed

RED

T1 self test local loopback

 

failed

YELLOW

Channels held in trunk processing

 

for this T1

FLASHING

Network loopback active for this

YELLOW

T1

 

 

NODAL SWITCH ANALOG LEVELS

SWITCH

FUNCTION

LEVEL

Six switches

Transmit =

Off adds loss

per channel

Analog to T1

 

 

Receive =

All switches off =

 

T1 to analog

0 dB

1

Receive -2 dB

Off = 2 dB lower

2

Receive -3 dB

Off = 3 dB lower

3

Receive -4 dB

Off = 4 dB lower

4Transmit -2 dB Off = 2 dB lower

5Transmit -3 dB Off = 3 dB lower

6Transmit -4 dB Off = 4 dB lower

NODAL SWITCH ANALOG SIGNALING

SWITCH

LABEL

FUNCTION

Four

Four switches

Off adds loss

switches

set card sig-

 

per card

naling options

Consult manual for

 

for all 12 chan

signaling option settings

 

 

per voice card type

1Option A Off = normal FXS

2Option B Off = normal FXS

3Option C Off = normal FXS

4Trunk proces- When TP or test:

 

sing (TP)

On = loop busy

 

Busy/Idle

Off = loop idle

 

 

 

 

 

 

 

BACKPANEL CHANNEL LEDs

 

 

COLOR

PER CHANNEL FUNCTION

 

 

OFF

Idle (FXS ground start , tip open

 

 

GREEN

Incoming call (FXS loop start

 

 

RED

Outgoing call

 

 

YELLOW

Answer (taking) condition

 

 

 

 

 

 

Top View

Figure 2-2: Access Bank II - SNMP Top Cover Installation Guide

2-4

9/24/01

Page 29
Image 29
Carrier Access SNMP manual Access Bank II Snmp Top Cover Installation Guide