APPLICATION

The QP4TETrash Pump is designed to be used for de-watering applications. Both the suction and discharge ports on the QP4TE pump use a 4-inch diameter opening, which allows the pump to pump at a rate of approximately 528 gallons/minute (gpm) or 2,000 liters/minute (lpm).

Trash pumps derive their name from their ability to handle a greater amount of debris and solids than standard centrifugal pumps.These pumps generally handle solids up to 1/2 the size of the discharge opening making them less likely to clog. Also trash pumps are capable of handling water with 25% solids by weight.

The advantage of using a trash pump is that it can be quickly and easily disassembled in the field "without tools" and easily cleaned when clogged.

Power Plant

This trash pump is powered by a 9 horsepower, air-cooled, 4-stroke, single-cylinder, ROBIN EX-270D50021gasoline engine that incorporates a low "Oil Alert Feature".

Oil Alert Feature

In the event of low oil or no oil, the engine has a built-in oil alarm engine shut-down feature. In the event the oil level is low the engine will automatically shut-down.

GENERAL INFORMATION

Suction Lift

This pump is intended to be used for dewatering applications and is capable of suction lifts up to 25 feet at sea level. For optimal suction lift performance keep the suction hose or line as short as possible. In general always put the pump as close to the water as possible.

Pump Support

The pump should always be placed on solid stationary ground in a level position.

NEVER place the pump on soft soil. The suction hose or pipe connection should always be checked for tightness and leaks. A small suction leak in the hose or fittings could prevent the pump from priming.

Elevation

Elevations over 3,000 feet will effect the performance of the pump. Due to less atmospheric pressure at higher altitudes, pumps DO NOT have the priming ability that they have at sea level.

A general rule of thumb is that for every 1,000 feet of elevation above sea level a pump will lose one foot of priming ability.

For example, in Flagstaff, Arizona where the elevation is approximately 7,000 feet, the pump would have a suction lift of only 18 feet rather than the 25 feet at sea level.

Please contact your nearest authorized MQ

NOTE dealer for any accessories that your pump may require.

PAGE 12 —OPERATION AND PARTS MANUAL — REV. #1 (10/10/08)

Image 12
Contents Model QP4TE Proposition 65 Warning Operation & Parts Manual REV. #0 01/25/06 Table of Contents Parts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Engine Safety Fuel Safety Transporting Safety Operation and Parts Manual REV. #1 10/10/08 General Information ApplicationSpecifications Pump Specifications Engine Specifications EnginePump Components Used in general de-watering applications. TypicalBasic Engine Initial ServicingPRE-INSPECTION Engine InspectionPRE-SETUP Pump Before StartingInitial START-UP Engine Initial START-UP Engine Normal ShutdownMaintenance Pump Pump Vacuum TestPressure reading may vary Maintenance Engine Engine Maintenance Schedule24 -OPERATION and Parts Manual REV. #1 10/10/08 Preparation for Long -TERM Storage Pump StorageTroubleshooting Engine Troubleshooting ENGINE/PUMP Explanation of Code in Remarks Column Suggested Spare Parts QP4TE 1 to 5 Units withPump Assy Pump Assy 32 -OPERATION and Parts Manual REV. #1 10/10/08 Part Name QTY Remarks Robin EX270D50220 Engine AIR Cleaner Assy Base CP Robin EX270D50220 Engine Camshaft Assy PIN, CAMSHAFT, 9DX78.5L Robin EX270D50220 Engine Carburetor Assy Valve Throttle Robin EX270D50220 Engine Crankcase Assy Robin EX270D50220 Engine Crankcase Assy Robin EX270D50220 Engine CRANKSHAFT/PISTON Assy Crankshaft CP Robin EX270D50220 Engine Cylinder Head Assy Collet Valve Robin EX270D50220 Engine Fueltank Assy Part Name Robin EX270D50220 Engine Governor Assy Governor Lever Robin EX270D50220 Engine Ignition COIL/FLYWHEEL Assy Robin EX270D50220 Engine Ignition COIL/FLYWHEEL Assy Robin EX270D50220 Engine Muffler Assy Muffler CP Robin EX270D50220 Engine OIL Sensor Assy OIL Sensor CP Robin EX270D50220 Engine Recoil Starter Assy LABEL, Trade Mark 64D Terms and Conditions of Sale Parts Operation and Parts Manual REV. #1 10/10/08 HERE’S HOW to GET Help