Before Starting:

CAUTION - General Safety Precautions

NEVER operate the pump in a confined area or enclosed area structure that does not provide ample free flow of air.

ALWAYS wear approved eye and hearing protection before operating the compactor.

Before Starting

1.Read safety instructions at the beginning of manual.

2.Place pump as near to water as possible,onafirmflat,levelsurface.

3.Toprimepump,removefillcap(Figure2)andfillpumpcasing with water. If the pump casing is not filled with water before starting, it will not begin pumping.

CAUTION - Pump Casing

Pump casing must be filled with water before using pump. Otherwise pump will not be able to begin pumping.

WARNING - Fill Cap

DO NOT open fill cap if pump is hot! Water inside may be under pressure.

4.Checkforleaksbetweenpumpandengine.Ifwaterisleaking between the pump and engine housing, the seal inside the pump may be worn or damaged. Continued operation of the pumpisnot recommended.Furtherusageofthe pumpunder theseconditionsmaycauseseverewaterdamagetoengine.

Hoses and Clamps

1.Check that all hoses are securely attached to the pump. Make certain suction hose (Figure 2) does not have any air leakage.Tighten hose clamps and couplings as required.

2.Itisrecommendedthat 2 clampsbeusedwhensecuringthe suction hose to the inlet side (suction) of the pump.

PRE-SETUP (PUMP)

3.Remember suction hoses must be rigid enough not to collapse when the pump is in operation.

4.Check that the discharge hose (Figure 2) is not restricted. Place hose so that it lays as straight as it is possible on the ground. Remove any twists or sharp bends from hose which may block the flow of water.

Suction and discharge hoses are

available from Multiquip. Contact

NOTE your nearest dealer for more information.

5.The discharge hose is usually a collapsible (thin-walled) hose, however if a thin-walled discharge hose is not avail- able, a rigid suction hose can be substituted in its place.

6.Make sure the suction strainer (Figure 2) is clean and securely attached to the water end of the suction hose. The strainer is designed to protect the pump by preventing large objects from being pulled into the pump.

CAUTION - Strainer

The strainer should be positioned so it will remain completely under water. Running the pump with the strainer above water for long periods can damage the pump.

CAUTION - Flammable Fluids

DO NOT pump flammable fluids, corrosive chemicals or fluids containing toxic substances. These fluids can create potentially dangerous health and environmental hazards. Contact local authorities for assistance.

CAUTION - Mechanical Seal

This pump uses a water-cooled mechanical seal to prevent water from seeping into the engine. The passage of water through the pump casing lubricates the seal and prevents it from overheating. NEVER! operate the pump without water in the casing as this will cause damage to the mechanical seal.

PAGE 18 —OPERATION AND PARTS MANUAL — REV. #1 (10/10/08)

Image 18
Contents Model QP4TE Proposition 65 Warning Operation & Parts Manual REV. #0 01/25/06 Table of Contents Parts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Engine Safety Fuel Safety Transporting Safety Operation and Parts Manual REV. #1 10/10/08 General Information ApplicationSpecifications Pump Specifications Engine Specifications EnginePump Components Used in general de-watering applications. TypicalBasic Engine Initial ServicingPRE-INSPECTION Engine InspectionPRE-SETUP Pump Before StartingInitial START-UP Engine Initial START-UP Engine Normal ShutdownMaintenance Pump Pump Vacuum TestPressure reading may vary Maintenance Engine Engine Maintenance Schedule24 -OPERATION and Parts Manual REV. #1 10/10/08 Preparation for Long -TERM Storage Pump StorageTroubleshooting Engine Troubleshooting ENGINE/PUMP Explanation of Code in Remarks Column Suggested Spare Parts QP4TE 1 to 5 Units withPump Assy Pump Assy 32 -OPERATION and Parts Manual REV. #1 10/10/08 Part Name QTY Remarks Robin EX270D50220 Engine AIR Cleaner Assy Base CP Robin EX270D50220 Engine Camshaft Assy PIN, CAMSHAFT, 9DX78.5L Robin EX270D50220 Engine Carburetor Assy Valve Throttle Robin EX270D50220 Engine Crankcase Assy Robin EX270D50220 Engine Crankcase Assy Robin EX270D50220 Engine CRANKSHAFT/PISTON Assy Crankshaft CP Robin EX270D50220 Engine Cylinder Head Assy Collet Valve Robin EX270D50220 Engine Fueltank Assy Part Name Robin EX270D50220 Engine Governor Assy Governor Lever Robin EX270D50220 Engine Ignition COIL/FLYWHEEL Assy Robin EX270D50220 Engine Ignition COIL/FLYWHEEL Assy Robin EX270D50220 Engine Muffler Assy Muffler CP Robin EX270D50220 Engine OIL Sensor Assy OIL Sensor CP Robin EX270D50220 Engine Recoil Starter Assy LABEL, Trade Mark 64D Terms and Conditions of Sale Parts Operation and Parts Manual REV. #1 10/10/08 HERE’S HOW to GET Help