pads

Do not allow the pads to contact other electrodes or metal parts that are in

 

contact with the patient.

 

PRECAUTIONS

device handling

The OnSite was designed to be sturdy and reliable for many different use

 

conditions. However, handling the OnSite too roughly can damage it or its

 

accessories and will invalidate the warranty. Check the OnSite and accessories

 

regularly for damage, according to directions.

maintenance

Improper maintenance may damage the OnSite or cause it to function improperly.

 

Maintain the OnSite according to directions.

skin burns

Do not let the pads touch each other or other electrodes, lead wires, dressings,

 

medicine patches, etc. Such contact can cause electrical arcing and skin burns

 

during a shock and may also divert the electrical current away from the patient’s

 

heart. During a shock, air pockets between the skin and pads can cause skin burns.

 

To help prevent air pockets, make sure pads stick well to the skin. Do not use

 

dried out pads because they will not provide good contact with the skin.

patient handling

Before delivering a shock, it is important to disconnect the patient from other

 

medical electrical equipment, such as blood-flow meters, that may not incorporate

 

defibrillation protection. In addition, make sure the pads are not in contact with

 

metal objects such as a bed frame or stretcher.

PHILIPS MEDICAL SYSTEMS

D-2

Image 42
Contents A r t S t a r t O n S i t e D e f i b r i l l a t o r EditionIntentionally blank HeartStart ChirpsIntentionally blank Quick Reference Intentionally blank HeartStart OnSite Important NoteIntentionally blank Philips Electronics North America Corp Philips Medical Systems, Seattle, WA, USAIntentionally blank Contents Appendices Sudden Cardiac Arrest Introduction to the HeartstartDescription Indications for USETraining and Practice National and Local RequirementsFor More Information Setting UP the Heartstart Onsite Package ContentsTop Back Philips Medical Systems Recommended Accessories Using the Heartstart Onsite OverviewPull the Green Handle Place the Pads Press the Shock Button Patient, and the Caution light begins flashing as a reminderTreating Infants and Children Remove the Infant/Child Pads Cartridge from its packageWhen Emergency Medical Services Arrive Do not Delay TreatmentReminders Philips Medical Systems Onsite Data Storage After Using the Heartstart OnsiteAfter Each USE Must be replaced after being usedPhilips Medical Systems Periodic Checks Routine MaintenanceMaintaining the Heartstart Onsite RemindersCleaning the Onsite Troubleshooting TipsDisposing of the Onsite Accessories for the Heartstart Onsite REF 68-PCHATPhilips Medical Systems CPR Glossary of TermsAED ECGNSA Periodic self-tests Blinking green Ready lightConsciousness, absence of respiration, and lack of a pulse See NSA pauseSCA Waveform See Smart biphasic waveformGlossary of SYMBOLS/CONTROLS Philips Medical Systems Symbol Philips Medical Systems Approved accessories are used Successful defibrillationOnSite on someone wearing an oxygen mask Precautions Physical Heartstart Onsite Defibrillator SpecificationsTechnical Information EnvironmentalControls and Indicators Category SealingSee Electromagnetic Conformity tables Defibrillation Waveform DeliveredCurrent a Disarm AED mode Shock-to-shock cycle timeNewborn 14 J/kg ECG Analysis System ECG Analysis Performance Category Battery type Capacity Accessories SpecificationsBattery M5070A Category Adult pads Infant/child padsEnvironmental Considerations Appropriate recycling facilityRegulations Configuration Device OptionsPatient Treatment Protocol Options Coaching parameter settings NSA pause type SettingsProtocol pause timer and CPR Pause, the OnSite returns to rhythmCPR4 Child pads cartridge is installed InstalledInfants and children when an infant Yes, NoPhilips Medical Systems Troubleshooting Testing and TroubleshootingTesting Recommended Action During AN EmergencyTroubleshooting While the Onsite is in USE Green Ready light is solid OnSite tells youTo insert a pads cartridge OnSite tells you To stop all motion Troubleshooting While the Onsite is not in USE Contact Philips for service if neededGreen Ready light is not on Behavior Emissions test Electromagnetic ConformityElectromagnetic Emissions CisprElectromagnetic Immunity ESDSeparation distance according to frequency of transmitter m Important Warnings and Reminders Environmental ConsiderationsShock Cycle Timing Intentionally blank Intentionally blank Intentionally blank Europe, Middle East, and Africa Philips Medical Systems United StatesCanada Latin America
Related manuals
Manual 70 pages 12.08 Kb

M5066A specifications

The Philips M5066A is a state-of-the-art multi-parameter patient monitor designed to enhance healthcare delivery in various clinical settings. This versatile monitoring solution is widely utilized in hospitals, especially in critical care units and during transport, owing to its robust features and reliable performance.

One of the main features of the M5066A is its ability to monitor multiple vital signs simultaneously, including ECG, heart rate, invasive and non-invasive blood pressure, respiration rate, temperature, and saturation levels. This multi-parameter capability allows healthcare professionals to gain a comprehensive view of a patient’s health status, enabling timely interventions and improved patient outcomes.

The M5066A incorporates advanced technologies such as Philips’ proprietary IntelliVue technology, which enhances the accuracy and reliability of vital sign measurements. The monitor uses sophisticated algorithms to filter out noise and interferences, ensuring that the data presented to caregivers is both precise and actionable. The device also supports a range of connectivity options, allowing for seamless integration with hospital information systems and electronic medical records (EMRs). This connectivity facilitates the easy transfer and management of patient data, promoting better coordination of care.

Another significant characteristic of the M5066A is its user-friendly interface. The large, high-resolution display provides clear visuals of vital sign trends and parameters, enabling quick assessments by healthcare professionals. Customizable alarms and alerts can be programmed to suit specific patient needs, ensuring that caregivers are notified of critical changes in a timely manner.

The M5066A is also designed with patient comfort and safety in mind. The device's compact and lightweight design facilitates easy transport, while its durable construction ensures reliability in demanding environments. Furthermore, the monitor's battery backup allows for continuous monitoring even during power outages or when moving patients between departments.

In conclusion, the Philips M5066A multi-parameter patient monitor is a sophisticated tool that enhances patient monitoring by providing accurate, real-time data. Its advanced technologies, comprehensive monitoring capabilities, user-friendly interface, and focus on safety and comfort make it an invaluable asset in any clinical setting, helping healthcare providers deliver the highest standard of care.