A r t S t a r t O n S i t e D e f i b r i l l a t o r
Intentionally blank
Chirps
HeartStart
Intentionally blank
Quick Reference
Intentionally blank
Important Note
HeartStart OnSite
Intentionally blank
Philips Medical Systems, Seattle, WA, USA
Philips Electronics North America Corp
Intentionally blank
Contents
Appendices
Indications for USE
Introduction to the Heartstart
Description
Sudden Cardiac Arrest
National and Local Requirements
Training and Practice
For More Information
Package Contents
Setting UP the Heartstart Onsite
Top Back
Philips Medical Systems
Recommended Accessories
Overview
Using the Heartstart Onsite
Pull the Green Handle
Place the Pads
Patient, and the Caution light begins flashing as a reminder
Press the Shock Button
Remove the Infant/Child Pads Cartridge from its package
Treating Infants and Children
Do not Delay Treatment
When Emergency Medical Services Arrive
Reminders
Philips Medical Systems
Must be replaced after being used
After Using the Heartstart Onsite
After Each USE
Onsite Data Storage
Philips Medical Systems
Reminders
Routine Maintenance
Maintaining the Heartstart Onsite
Periodic Checks
Troubleshooting Tips
Cleaning the Onsite
Disposing of the Onsite
REF 68-PCHAT
Accessories for the Heartstart Onsite
Philips Medical Systems
ECG
Glossary of Terms
AED
CPR
NSA
Blinking green Ready light
Periodic self-tests
Waveform See Smart biphasic waveform
See NSA pause
SCA
Consciousness, absence of respiration, and lack of a pulse
Glossary of SYMBOLS/CONTROLS
Philips Medical Systems
Symbol
Philips Medical Systems
Successful defibrillation
Approved accessories are used
OnSite on someone wearing an oxygen mask
Precautions
Environmental
Heartstart Onsite Defibrillator Specifications
Technical Information
Physical
Category Sealing
Controls and Indicators
See Electromagnetic Conformity tables
Delivered
Defibrillation Waveform
Current a
Shock-to-shock cycle time
Disarm AED mode
Newborn 14 J/kg
ECG Analysis System
ECG Analysis Performance
Category Adult pads Infant/child pads
Accessories Specifications
Battery M5070A
Category Battery type Capacity
Appropriate recycling facility
Environmental Considerations
Regulations
Device Options
Configuration
Patient Treatment Protocol Options
Pause, the OnSite returns to rhythm
NSA pause type Settings
Protocol pause timer and CPR
Coaching parameter settings
CPR4
Yes, No
Installed
Infants and children when an infant
Child pads cartridge is installed
Philips Medical Systems
Recommended Action During AN Emergency
Testing and Troubleshooting
Testing
Troubleshooting
Green Ready light is solid OnSite tells you
Troubleshooting While the Onsite is in USE
To insert a pads cartridge
OnSite tells you To stop all motion
Contact Philips for service if needed
Troubleshooting While the Onsite is not in USE
Green Ready light is not on Behavior
Cispr
Electromagnetic Conformity
Electromagnetic Emissions
Emissions test
ESD
Electromagnetic Immunity
Separation distance according to frequency of transmitter m
Environmental Considerations
Important Warnings and Reminders
Shock Cycle Timing
Intentionally blank
Intentionally blank
Intentionally blank
Latin America
Philips Medical Systems United States
Canada
Europe, Middle East, and Africa