Philips M5066A Yes, No, Optional CPR Coaching includes, By the CPR Coaching, Installed

Page 55

PHILIPS MEDICAL SYSTEMS

parameter

CPR Coaching adult ventilation instruction

CPR Coaching infant/child ventilation instruction

CPR Coaching compression:ventilation ratio

settings

default

default description

Yes, No

Yes

Optional CPR Coaching includes

 

 

rescue breaths at the rate determined

 

 

by the CPR Coaching

 

 

compression:ventilation ratio for

 

 

adults when an adult pads cartridge is

 

 

installed.

 

 

NOTE: if this parameter is configured to

 

 

NO, CPR Coaching will always be

 

 

compressions-only when an adult pads

 

 

cartridge is installed.

Yes, No

Yes

Optional CPR Coaching includes

 

 

rescue breaths at the rate determined

 

 

by the CPR Coaching

 

 

compression:ventilation ratio for

 

 

infants and children when an infant/

 

 

child pads cartridge is installed.

 

 

NOTE: if this parameter is configured to

 

 

NO, CPR Coaching will always be

 

 

compressions-only when an infant/child

 

 

pads cartridge is installed.

• 30:2 adult and

30:2 adult and

If the user presses the i-button for

30:2 infant/child

30:2 infant/

optional CPR Coaching during a

• 30:2 adult and

child

protocol pause or NSA pause, the

 

OnSite provides coaching in basic CPR

15:2 infant/child

 

 

for cycles of 30 compressions and 2

• 15:2 adult and

 

 

ventilations for adults, children, and

15:2 infant/child

 

infants. Pauses begin and end with

 

 

compressions.

E

F-5

Image 55
Contents Edition A r t S t a r t O n S i t e D e f i b r i l l a t o rIntentionally blank Chirps HeartStartIntentionally blank Quick Reference Intentionally blank Important Note HeartStart OnSiteIntentionally blank Philips Medical Systems, Seattle, WA, USA Philips Electronics North America CorpIntentionally blank Contents Appendices Indications for USE Introduction to the HeartstartDescription Sudden Cardiac ArrestNational and Local Requirements Training and PracticeFor More Information Package Contents Setting UP the Heartstart OnsiteTop Back Philips Medical Systems Recommended Accessories Overview Using the Heartstart OnsitePull the Green Handle Place the Pads Patient, and the Caution light begins flashing as a reminder Press the Shock ButtonRemove the Infant/Child Pads Cartridge from its package Treating Infants and ChildrenDo not Delay Treatment When Emergency Medical Services ArriveReminders Philips Medical Systems Must be replaced after being used After Using the Heartstart OnsiteAfter Each USE Onsite Data StoragePhilips Medical Systems Reminders Routine MaintenanceMaintaining the Heartstart Onsite Periodic ChecksTroubleshooting Tips Cleaning the OnsiteDisposing of the Onsite REF 68-PCHAT Accessories for the Heartstart OnsitePhilips Medical Systems ECG Glossary of TermsAED CPRNSA Blinking green Ready light Periodic self-testsWaveform See Smart biphasic waveform See NSA pauseSCA Consciousness, absence of respiration, and lack of a pulseGlossary of SYMBOLS/CONTROLS Philips Medical Systems Symbol Philips Medical Systems Successful defibrillation Approved accessories are usedOnSite on someone wearing an oxygen mask Precautions Environmental Heartstart Onsite Defibrillator SpecificationsTechnical Information PhysicalCategory Sealing Controls and IndicatorsSee Electromagnetic Conformity tables Delivered Defibrillation WaveformCurrent a Shock-to-shock cycle time Disarm AED modeNewborn 14 J/kg ECG Analysis System ECG Analysis Performance Category Adult pads Infant/child pads Accessories SpecificationsBattery M5070A Category Battery type CapacityAppropriate recycling facility Environmental ConsiderationsRegulations Device Options ConfigurationPatient Treatment Protocol Options Pause, the OnSite returns to rhythm NSA pause type SettingsProtocol pause timer and CPR Coaching parameter settingsCPR4 Yes, No InstalledInfants and children when an infant Child pads cartridge is installedPhilips Medical Systems Recommended Action During AN Emergency Testing and TroubleshootingTesting TroubleshootingGreen Ready light is solid OnSite tells you Troubleshooting While the Onsite is in USETo insert a pads cartridge OnSite tells you To stop all motion Contact Philips for service if needed Troubleshooting While the Onsite is not in USEGreen Ready light is not on Behavior Cispr Electromagnetic ConformityElectromagnetic Emissions Emissions testESD Electromagnetic ImmunitySeparation distance according to frequency of transmitter m Environmental Considerations Important Warnings and RemindersShock Cycle Timing Intentionally blank Intentionally blank Intentionally blank Latin America Philips Medical Systems United StatesCanada Europe, Middle East, and Africa
Related manuals
Manual 70 pages 12.08 Kb

M5066A specifications

The Philips M5066A is a state-of-the-art multi-parameter patient monitor designed to enhance healthcare delivery in various clinical settings. This versatile monitoring solution is widely utilized in hospitals, especially in critical care units and during transport, owing to its robust features and reliable performance.

One of the main features of the M5066A is its ability to monitor multiple vital signs simultaneously, including ECG, heart rate, invasive and non-invasive blood pressure, respiration rate, temperature, and saturation levels. This multi-parameter capability allows healthcare professionals to gain a comprehensive view of a patient’s health status, enabling timely interventions and improved patient outcomes.

The M5066A incorporates advanced technologies such as Philips’ proprietary IntelliVue technology, which enhances the accuracy and reliability of vital sign measurements. The monitor uses sophisticated algorithms to filter out noise and interferences, ensuring that the data presented to caregivers is both precise and actionable. The device also supports a range of connectivity options, allowing for seamless integration with hospital information systems and electronic medical records (EMRs). This connectivity facilitates the easy transfer and management of patient data, promoting better coordination of care.

Another significant characteristic of the M5066A is its user-friendly interface. The large, high-resolution display provides clear visuals of vital sign trends and parameters, enabling quick assessments by healthcare professionals. Customizable alarms and alerts can be programmed to suit specific patient needs, ensuring that caregivers are notified of critical changes in a timely manner.

The M5066A is also designed with patient comfort and safety in mind. The device's compact and lightweight design facilitates easy transport, while its durable construction ensures reliability in demanding environments. Furthermore, the monitor's battery backup allows for continuous monitoring even during power outages or when moving patients between departments.

In conclusion, the Philips M5066A multi-parameter patient monitor is a sophisticated tool that enhances patient monitoring by providing accurate, real-time data. Its advanced technologies, comprehensive monitoring capabilities, user-friendly interface, and focus on safety and comfort make it an invaluable asset in any clinical setting, helping healthcare providers deliver the highest standard of care.