Hampton Bay H200 installation manual Mobile Home Installation

Page 16

INSTALLATION

MOBILE HOME INSTALLATION

Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit.

Place your unit in position and secure it to the floor using four lag bolts 1/4" through the four holes inside the legs. It is important to maintain the structural integrity of the Mobile Home floor, walls and roof when installing your unit.

For Mobile Home units installed in the U.S. the unit must be grounded using a #8 ground wire with approved termination and star washer.

CAUTION: At no time use unlabelled parts, or substitute parts made for another chimney system.

Install as per chimney manufacturer's installation instructions.

IMPORTANT

DO NOT CONNECT TO OR USE IN CON- JUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY AP- PROVED FOR SUCH INSTALLATIONS.

If desired, the air for combustion may be drawn directly from the outside of the house, as detailed below. It is not obligatory to do this, but it may help combustion in small or poorly ventilated house.

Connect a 4" (100 mm) diameter stainless steel, or other non-combustible corrosion resistant material, to the O.S.Ahook-up box. In order to do this the O.S.Ahook-up box must be connected to the base using 1/2" (12 mm) hex head bolts.

Run the pipe (up to 54" (1372 mm) long) to the outside avoiding sharp bends and joints within cavity walls. Turn the end down and fit corrosion resistant mesh to prevent the entry of leaves and rodents. Seal the penetration of the outside wall with silicon.

WARNING: Do not obstruct free air supply to the air inlet duct located at the back of the stove.

NOTE: Listed factory built chimney con- nectors including elbows are acceptable for use in Mobile Home Installations.

In addition to standard installation instructions the following requirements are mandatory for installation in a mobile home.

1)The stove must be permanently bolted to the floor of the Mobile Home using the floor screws provided.

2)The stove must have a permanent outside air source for combustion.

3)The stove must be electrically grounded to the steel chassis of the Mobile Home.

4)A listed double-wall connector chimney system, roof thimble, spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used.

5)If the chimney exits the Mobile Home at a location other than through the roof, and exits at a point 7ft. (2130mm) or less above the ground level on which the Mobile Home is positioned a guard or method of enclosing the chimney shall be fitted at the point of exit for a height up to 7ft. (2130mm).

6)The chimney shall be attached directly to the room heater and shall extend at least 3 ft. (914mm) above the part of the roof through which it passes. The top of the chimney should project at least 2ft. (610mm) above the highest elevation of any part of the Mobile Home within 10 ft. (3048mm) of the chimney.

7)The chimney system shall comply with Local Requirements.

8)Any openings in a chimney guard where required must not permit the entrance of 3/4" (19mm) diameter rod.

9)CAUTION: THE STRUCTURAL INTEG- RITY OF THE MOBILE HOME ROOF, FLOOR, WALLS AND CEILING MUST BE MAINTAINED.

10)Check any other local building code as other local codes may apply.

11)WARNING: DO NOT INSTALL INASLEEP- ING ROOM OF A MOBILE HOME.

12)Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure.

16

Hampton H200 Cast Freestanding Woodstove

Image 16
Contents Freestanding Woodstove Hampton Fireplace Product Table of Contents Safety Label 290Installation Unit Dimensions with Standard LegsUnit Dimensions with Optional Short Legs Draft Control Lever Handle PRE-INSTALLATION AssemblyRotating Elbow Residential Installation Modular Installation OptionsResidential Installation C Vent Single Wall Minimum Clearance to Combustible MaterialsMinimum Alcove Clearance to Combustible Materials Additional Clearances For Backwall ExitMinimum Clearance to Combustibles Minimum Clearance to Non-CombustiblesFloor Protection Step bSTEP-BY-STEP Chimney Connector Installation Factory Built ChimneyMasonry Chimney Masonry FireplaceCombustible Wall Chimney Connector PASS-THROUGHS Method a 12 304.8 mm Clearance to Combustible Wall MemberRecommended Heights for Woodstove Flue Example bMobile Home Installation Installation Listed Components For Mobile Home InstallationCanadian Installations Optional Short LEG Installation Brick InstallationDoor Removal Optional BLOWER/FAN Installation Back ShieldOptional Side Shelf Installation Underside of Side Shelf ShownOptional ASH Drawer KIT Installation Andiron BricksOperating Instructions Operating InstructionsFAN Operation First FireSafety Guidelines Draft ControlASH Disposal Safety PrecautionsOptional Ash Drawer Operating Guideline Maintenance Handle Replacement Latch Adjustment MethodBe changed after adjustment Front Door GasketTOP Baffle Replacement Parts List H200 Main AssemblyParts List H200 Door Assembly PART# DescriptionH200 ASH Drawer Assembly H200 FAN Assembly 910-157 FAN ThermodiscHampton H200 Cast Freestanding Woodstove Hampton H200 Cast Freestanding Woodstove Warranty ConditionsInstaller Please complete the following information

H200 specifications

The Hampton Bay H200 is a standout model in the realm of outdoor heating solutions, providing both comfort and style for outdoor spaces. As homeowners increasingly seek to extend their enjoyment of patios and backyards, the H200 delivers with an impressive range of features, cutting-edge technologies, and thoughtful design characteristics.

One of the key features of the Hampton Bay H200 is its powerful heating capability. Equipped with a high-efficiency burner, it generates a substantial amount of heat, making it suitable for use on chilly evenings. With an adjustable heat setting, users can easily customize the temperature to suit their comfort level and specific outdoor conditions.

The H200 is also designed with energy efficiency in mind. Its innovative burner technology ensures that it utilizes fuel efficiently, allowing for longer usage times without frequent refueling. This not only saves on operational costs but also reduces the environmental impact associated with outdoor heating.

Portability is another prominent characteristic of the H200. It features a lightweight construction with easy-to-move wheels, enabling users to relocate the heater effortlessly. Whether moving it closer to a gathering or storing it away during warmer months, the H200 makes it convenient to adapt to changing outdoor needs.

Durability is crucial in any outdoor appliance, and the Hampton Bay H200 does not disappoint. Constructed from high-quality materials, it is built to withstand the elements, ensuring longevity and reliable performance. The sleek and modern design with a weather-resistant finish not only enhances its durability but also adds an attractive aesthetic to any outdoor setting.

Safety is a top priority for outdoor heating equipment, and the H200 is equipped with several safety features that provide peace of mind. The automatic shut-off function activates if the heater is tipped over, helping to prevent accidents. Additionally, the safety grid protects users from direct contact with the hot surfaces, reducing the risk of burns.

In summary, the Hampton Bay H200 is a formidable option for anyone looking to enhance their outdoor space. With its powerful heating capabilities, energy-efficient burner technology, portability, durability, and robust safety features, it is well-equipped to offer warmth and comfort in any outdoor environment. Its stylish design seamlessly integrates into various outdoor aesthetics, making it a versatile choice for patios, decks, and gardens alike.