Hampton Bay H200 installation manual Operating Instructions, FAN Operation, First Fire

Page 22

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

With your unit now correctly installed and safety inspected by your local authority, you are now ready to start a fire. Before establishing your first fire, it is important that you fully understand the operation of your draft control.

See below, First Fire section, for details.

3)With the draft still in the fully open position add two or three seasoned logs to your fire. Form a trench in the ash bed to allow air to reach the rear of the firebox prior to closing the door.

4)After about 45 minutes, when your wood has begun to burn strongly, adjust your draft control down to keep the fire at a moderate level.

13)All fuel burning appliances consume oxygen during operation. It is important that you supply a source of fresh air to your unit while burning. A slightly opened window is sufficient for the purpose. If you also have a fireplace in your home, a downdraft may be created by your Hampton Stove causing a draft down your chimney. If this occurs, slightly open a window near your unit.

FAN OPERATION

Automatic

To operate the optional fan automatically, push the bottom switch on the side of the fan housing to "AUTO" and the top switch to either "HIGH" or "LOW" for fan speed.

This will allow the fan to turn on as the stove has come up to operating temperature. It will also shut the fan system off after the fire has gone out and the unit cooled to below a useful heat output range.

Manual

To manually operate the fan system push the bot- tom switch to "MAN" and the top switch to either "HIGH" or "LOW". This will bypass the sensing device and allow full control of the fan.

Switching from "AUTO" to "MAN" or "HIGH" to "LOW" may be done anytime.

FIRST FIRE

When your installation is completed and in- spected you are ready for your first fire.

1)Open control fully.

2)Open firebox door and build a small fire us- ing paper and dry kindling on the firebrick hearth. Secure door on the firebox and wait a few minutes for a good updraft in the flue to establish the fire. (Leaving the door slightly open will help your fire start more rapidly.)

CAUTION: Never leave unit unat- tended if door is left open. This procedure is for fire start-up only, as unit may overheat if door is left open for too long.

WARNING: Never build a roaring fire in a cold stove. Always warm your stove up slowly!

5)Once a bed of coals has been established on the firebrick hearth, you may adjust the draft control to a low setting to operate the unit at its most efficient mode.

6)During the first few fires, keep the combus- tion rate at a moderate level and avoid a large fire. Only after 5 or 6 such fires can you operate the stove at its maximum setting, and only after the metal has been warmed.

7)For the first few days, the stove will give off an odour from the paint. This is to be expected as the high temperature paint becomes seasoned. Windows and/or doors should be left open to provide adequate ventilation while this temporary condition exists. Burning the stove at a very high temperature the first few times may damage the paint. Burn fires at a moderate level the first few days.

8)Do not place anything on the stove top during the curing process. This may result in damage to your paint finish.

9)During the first few days it may be more difficult to start the fire. As you dry out your firebrick and your masonry flue, your draft will increase.

10)For those units installed at higher elevations or into sub-standard masonry fireplaces, drafting problems may occur. Consult an experienced dealer or mason on methods of increasing your draft.

11)Some cracking and popping noises may be experienced during the heating up process. These noises will be minimal when your unit reaches temperature.

12)Before opening your door to reload, open draft fully for approximately 10 to 15 seconds until fire has been re-established. This will minimize any smoking.

CAUTION: If the body of your unit, flue baffle or any part of the chimney connector starts to glow, you are over- firing. Stop loading fuel immediately and close the draft control until the glow has completely subsided.

14)Green or wet wood is not recommended for your unit. If you must add wet or green fuel, open the draft control fully until all moisture has been dispersed by the intense fire. Once all moisture has been removed, the draft control may be adjusted to maintain the fire.

15)If you have been burning your stove on a low draft, use caution when opening the door. After opening the damper, open the door a crack, and allow the fire to adjust before fully opening the door.

16)The controls of your unit or the air supply passages should not be altered to increase firing for any reason.

17)If you burn the unit too slowly or at too low a setting your unit will not be operating as efficiently as it can. An easy rule of thumb says that if your glass is clean, then your flue is clean and your exhaust is clean. Burn the stove hot enough to keep your glass clean and you won't need to clean your flue as often.

22

Hampton H200 Cast Freestanding Woodstove

Image 22
Contents Freestanding Woodstove Hampton Fireplace Product Table of Contents Safety Label 290Installation Unit Dimensions with Standard LegsUnit Dimensions with Optional Short Legs Draft Control Lever Handle PRE-INSTALLATION AssemblyRotating Elbow Residential Installation Modular Installation OptionsResidential Installation C Vent Single Wall Minimum Clearance to Combustible MaterialsMinimum Clearance to Combustibles Minimum Alcove Clearance to Combustible MaterialsAdditional Clearances For Backwall Exit Minimum Clearance to Non-CombustiblesFloor Protection Step bSTEP-BY-STEP Chimney Connector Installation Factory Built ChimneyMasonry Chimney Masonry FireplaceCombustible Wall Chimney Connector PASS-THROUGHS Method a 12 304.8 mm Clearance to Combustible Wall MemberRecommended Heights for Woodstove Flue Example bMobile Home Installation Installation Listed Components For Mobile Home InstallationCanadian Installations Optional Short LEG Installation Brick InstallationDoor Removal Optional BLOWER/FAN Installation Back ShieldOptional Side Shelf Installation Underside of Side Shelf ShownOptional ASH Drawer KIT Installation Andiron BricksFAN Operation Operating InstructionsOperating Instructions First FireSafety Guidelines Draft ControlASH Disposal Safety PrecautionsOptional Ash Drawer Operating Guideline Maintenance Be changed after adjustment Handle ReplacementLatch Adjustment Method Front Door GasketTOP Baffle Replacement Parts List H200 Main AssemblyParts List H200 Door Assembly PART# DescriptionH200 ASH Drawer Assembly H200 FAN Assembly 910-157 FAN ThermodiscHampton H200 Cast Freestanding Woodstove Hampton H200 Cast Freestanding Woodstove Warranty ConditionsInstaller Please complete the following information

H200 specifications

The Hampton Bay H200 is a standout model in the realm of outdoor heating solutions, providing both comfort and style for outdoor spaces. As homeowners increasingly seek to extend their enjoyment of patios and backyards, the H200 delivers with an impressive range of features, cutting-edge technologies, and thoughtful design characteristics.

One of the key features of the Hampton Bay H200 is its powerful heating capability. Equipped with a high-efficiency burner, it generates a substantial amount of heat, making it suitable for use on chilly evenings. With an adjustable heat setting, users can easily customize the temperature to suit their comfort level and specific outdoor conditions.

The H200 is also designed with energy efficiency in mind. Its innovative burner technology ensures that it utilizes fuel efficiently, allowing for longer usage times without frequent refueling. This not only saves on operational costs but also reduces the environmental impact associated with outdoor heating.

Portability is another prominent characteristic of the H200. It features a lightweight construction with easy-to-move wheels, enabling users to relocate the heater effortlessly. Whether moving it closer to a gathering or storing it away during warmer months, the H200 makes it convenient to adapt to changing outdoor needs.

Durability is crucial in any outdoor appliance, and the Hampton Bay H200 does not disappoint. Constructed from high-quality materials, it is built to withstand the elements, ensuring longevity and reliable performance. The sleek and modern design with a weather-resistant finish not only enhances its durability but also adds an attractive aesthetic to any outdoor setting.

Safety is a top priority for outdoor heating equipment, and the H200 is equipped with several safety features that provide peace of mind. The automatic shut-off function activates if the heater is tipped over, helping to prevent accidents. Additionally, the safety grid protects users from direct contact with the hot surfaces, reducing the risk of burns.

In summary, the Hampton Bay H200 is a formidable option for anyone looking to enhance their outdoor space. With its powerful heating capabilities, energy-efficient burner technology, portability, durability, and robust safety features, it is well-equipped to offer warmth and comfort in any outdoor environment. Its stylish design seamlessly integrates into various outdoor aesthetics, making it a versatile choice for patios, decks, and gardens alike.