Desa SVYD18NRA, SVYD18PRA Checking GAS Connections, Test Pressures In Excess Of 1/2 Psig 3.5 kPa

Page 13

INSTALLATION

Continued

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

 

PROPANE/LP

 

From External

CSA Design-Certified

Regulator

(11" W.C. to 14"

Equipment Shutoff Valve

With 1/8" NPT Tap*

W.C. Pressure)

NATURAL

Approved

From Gas

Flexible Gas

Meter (5" W.C.

Hose (if

to 10.5" W.C.

allowed by

Pressure)

local codes)

 

3" Min

 

Cap Pipe Tee

Gas Control

Nipple Joint

 

Sediment Trap

Figure 16 - Gas Connection

(SVYD18PRA/NRA Series)

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 27.

**Minimum inlet pressure for purpose of input adjustment.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater.SeeguidelinesunderCon- necting to Gas Supply, page 11.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equip- ment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

4.Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 17).

CHECKING GAS CONNECTIONS

WARNING: Test all gas pip- ing and connections, internal and external to unit, for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak.

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air.

3.Check all joints from gas meter for natural or propane/LP supply to equipment shutoff valve (see Figure 18 or 19, page 14). Apply a non- corrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Apply a noncorrosive leak de- tection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Equipment Shutoff Valve

OpenN

POSIT

Closed

Figure 17 - Equipment Shutoff Valve

113084-01C

www.desatech.com

13

Image 13
Contents Victor Hearth OxfordTable of Contents Safety Information Product Identification Local Codes Product FeaturesAIR for Combustion Ventilation Unusually Tight Construction Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationClearances to Combustibles Minimum Wall and Ceiling Clearances see ,Lift off corrugated box enclosing stove body crating Stove Cavity Assembly Bolt Stop Connecting to GAS Supply Installing GAS LOG Into StoveSide View Installation Items NeededTest Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Ignitor Button Flame Adjustment KnobShutting Off Heater Manual Mode Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbPilot Flame Pattern Inspecting BurnersBurner Primary AIR Holes Main BurnerBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceObserved Problem Possible Cause Remedy TroubleshootingReplace burner orifice Gas leak. See Warning Observed Problem Possible Cause RemedyModels SVYD18PRA and SVYD18NRA Illustrated Parts BreakdownParts List Oxford Stove Body Victor Hearth Stove KEY Part Number Description QTY Replacement Parts SpecificationsWiring Diagram Service HintsAccessories Keep this Warranty Warranty InformationLimited Warranty