INSTALLATION
Connecting to Gas Supply
11
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pres- sure regulator.
WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.
CAUTION: Never connect propane/LP heater di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.
WARNING: Never connect natural gas heater to private
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•external regulator - propane/LP only (supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
*A CSA
The gas inlet connection for the stove heater is located on the lower
For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 20. Pointing the vent down protects it from freezing rain or sleet.
Side View | Back | Back View |
| Stove |
|
Stove | Panel |
|
Product |
| |
Unit |
| |
Identification |
| |
Front |
| |
Label |
| |
|
| |
| Gas Inlet |
|
| Connection |
|
| Access |
|
| Gas Log Heater |
Figure 19 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
Propane/LP
Supply Tank
External
Regulator
Vent Pointing
Down
Figure 20 - External Regulator With Vent Pointing Down
CAUTION: Use only new, black iron or steel pipe.
Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21 on page 12 for SVYD18PR/NR and FSVYD18PR/NR series, or Figure 22 on page 12 for SVYD18P/N and FSVYD18P/N series).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliances.
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.