Desa SVYD18NR, SVYD18N Check GAS Type, Clearances to Combustibles, Vent-Free Operation Only

Page 7

INSTALLATION

Check Gas Type Clearances to Combustibles

7

INSTALLATION

Continued

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought fireplace for proper type fireplace.

CLEARANCES TO COMBUSTIBLES

(Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceil- ing, and adjoining side and back walls.

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top.

Minimum Wall and Ceiling Clearances (see Figure 4)

A.Clearances from outermost point of stove top to any combus- tible side wall should not be less than 12 inches.

B.Clearances from outermost point of stove top to any combus- tible back wall should not be less than 6 inches (Includes Cor- ner Installations).

C.Clearances from the stove top to the ceiling should not be less than 48 inches.

Ceiling

48"

Minimum

Front View

Side Wall

12"

12"

Side Wall

Minimum

 

Minimum

 

 

 

Back Wall

 

 

6 "

 

 

 

Minimum

 

 

12 "

 

12 "

 

Minimum

 

Minimum

Side Wall

 

 

Side Wall

 

 

Top View

Front of

Corner

 

Wall

 

Stove Unit

 

 

6 "

 

 

 

Minimum

 

 

 

 

Ceiling

Wall

6 "

 

 

 

Minimum

 

 

 

 

 

48"

 

 

 

Minimum

 

 

 

Back Wall

 

 

 

6"

 

 

 

Minimum

Front of

Stove Unit

Side View

Floor

Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on Model)

For morevisit www..com

111162-01A

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsLocal Codes Product IdentificationAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingMinimum Wall and Ceiling Clearances see Figure Check GAS TypeClearances to Combustibles Vent-Free Operation OnlyAmity and Townsend Models Stove Cavity AssemblyStove Bottom Washers Bolt Stove Unit Sheraton ModelsFastening Heater Base to Stove Drop Bottom Installing GAS LOG Heater Into StoveInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemRemote Ready Models SVYD18PR/NR and FSVYD18PR/NR For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesOperating Heater Variable Control OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Observed Problem Possible Cause Models SVYD18PR, SVYD18NR FSVYD18PR and FSVYD18NR Illustrated Parts BreakdownKEY Part Number FSVYD18PR FSVYD18NR Description QTY Parts ListModels SVYD18P, SVYD18N, FSVYD18P and FSVYD18N KEY FSVYD18P FSVYD18N Description Indicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Sheraton NSCIVF* Series Parts List Townsend FC* and PFC* Series FC* and PFC* Series *Indicates Color Suffix Designation TownsendService Hints SpecificationsWiring Diagram Replacement PartsOwners Registration Form Postage Required Accessories Warranty Information