Desa SVYD18NR, SVYD18N ON/OFF Series Model Ghrcb, Thermostat Series Model Ghrctb, Manual Mode

Page 15

OPERATING HEATER (Remote Ready Models)

Optional Hand-Held Remote Operation (Cont.)

OPERATING HEATER (Manual-Variable Control Models)

For Your Safety Read Before Lighting

15

OPERATING HEATER

Continued

IMPORTANT: Do not leave the selector switch in the RE- MOTE or ON position when the pilot is not lit. This will drain the battery.

Flame Adjustment Knob

IH

 

F

PIL

ON

 

O

O

F

T

OFF

 

O

 

 

 

 

N

REMOTE

 

 

 

LO

 

 

 

Remote Selector Switch in Remote

Control Knob in

Position (Optional Remote Control)

On Position

Figure 28 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 29).

TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 29 - On/Off Hand-Held Remote Control Unit (GHRCB)

THERMOSTAT SERIES (MODEL GHRCTB)

The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 30). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Digital Display

Turns Remote On

Shows

or Off and Allows

Temperature and

You to Choose the

Settings

Manual Setting

 

Turns Burners

Selects Auto

On or Off

Setting

 

Decreases Room

Increases Room

Temperature in

Temperature in

AUTO Mode

AUTO Mode

 

 

Locks System to

 

Prevent Accidental

 

Ignition

Figure 30 - Thermostat Hand-Held Remote Control Unit (GHRCTB)

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahr- enheit (28 degrees Centigrade), the hand-held remote con- trol will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand- held remote to control the room temperature. If the hand- held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

For morevisit www..com

111162-01A

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsLocal Codes Product IdentificationAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingMinimum Wall and Ceiling Clearances see Figure Check GAS TypeClearances to Combustibles Vent-Free Operation OnlyAmity and Townsend Models Stove Cavity AssemblyStove Bottom Washers Bolt Stove Unit Sheraton ModelsFastening Heater Base to Stove Drop Bottom Installing GAS LOG Heater Into StoveInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemRemote Ready Models SVYD18PR/NR and FSVYD18PR/NR For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Manual ModeAuto Thermostatic Mode Safety FeaturesOperating Heater Variable Control OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Observed Problem Possible Cause Models SVYD18PR, SVYD18NR FSVYD18PR and FSVYD18NR Illustrated Parts BreakdownKEY Part Number FSVYD18PR FSVYD18NR Description QTY Parts ListModels SVYD18P, SVYD18N, FSVYD18P and FSVYD18N KEY FSVYD18P FSVYD18N Description Indicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Sheraton NSCIVF* Series Parts List Townsend FC* and PFC* Series FC* and PFC* Series *Indicates Color Suffix Designation TownsendService Hints SpecificationsWiring Diagram Replacement PartsOwners Registration Form Postage Required Accessories Warranty Information