Desa SVYD18N, SVYD18NR, SVYD18NR, SVYD18N installation manual Maintenance

Page 20

20

TROUBLESHOOTING

TROUBLESHOOTING

Continued

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP or natural gas

 

 

 

 

 

company

 

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 18) or replace burner orifice

 

 

 

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 18) or replace burner orifice

 

 

2.

Damaged burner

2.

Replace damaged burner

 

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

 

Maintenance, page 18)

 

 

2.

Gas regulator defective

2.

Replace gas control

 

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

 

and logs curing

 

operation

 

 

 

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

 

burner is lit

 

when burner is cold

 

let warm up for a minute

 

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

 

pane/LP or natural gas company

 

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

 

ances (see page 7)

 

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

 

nance, page 18) or replace burner orifice

 

 

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Gas

 

 

 

 

 

Log Heater Into Stove, page 10 )

 

 

2.

Drafts or other air currents affecting

2.

Eliminate source of drafts around heater

 

 

 

flame pattern

 

 

 

 

 

3.

Air holes at burner inlet blocked

3.

Clean out air holes at burner inlet. Peri-

 

 

 

 

 

odically repeat as needed

 

 

4.

Burner flame holes blocked

4.

Remove blockage or replace burner

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Remote does not function

1. Battery is not installed. Battery power

 

is low

1.Replace 9-volt batteries in receiver and hand-held remote control

Forvisit..com

111162-01A

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Local CodesProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsCheck GAS Type Clearances to CombustiblesVent-Free Operation Only Minimum Wall and Ceiling Clearances see FigureStove Cavity Assembly Amity and Townsend ModelsSheraton Models Stove Bottom Washers Bolt Stove UnitInstalling GAS LOG Heater Into Stove Fastening Heater Base to Stove Drop BottomConnecting to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsFor Your Safety Read Before Lighting Pressure Testing Heater Gas ConnectionsOperating Heater Remote Ready Models SVYD18PR/NR and FSVYD18PR/NRManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Shutting Off HeaterManual Mode Auto Thermostatic ModeSafety Features ON/OFF Series Model GhrcbVariable Control Operation Operating HeaterInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Observed Problem Possible Cause Illustrated Parts Breakdown Models SVYD18PR, SVYD18NR FSVYD18PR and FSVYD18NRParts List KEY Part Number FSVYD18PR FSVYD18NR Description QTYModels SVYD18P, SVYD18N, FSVYD18P and FSVYD18N KEY FSVYD18P FSVYD18N Description Amity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationKEY Part Description QTY Sheraton NSCIVF* Series Parts List Townsend FC* and PFC* Series Townsend FC* and PFC* Series *Indicates Color Suffix DesignationSpecifications Wiring DiagramReplacement Parts Service HintsOwners Registration Form Postage Required Accessories Warranty Information