Enviro EG28 DV, EG28-120 owner manual 33a-2002 Test Methods and the Resulting ITS/WH

Page 26

Initial Installation

QUALIFIED INSTALLERS ONLY

VENTING INTO A CLASS ‘A’ CHIMNEY:

This model is also certified and tested to vent into CLASS ‘A’ wood stove chimneys. Place the freestanding direct vent appliance in the desired location.

Use a conversion kit from Simpson Duravent (931, 932, or 933), or Security Chimney (SV4CCK1, SV4CCK2, or SV4CCK1). Which kit is used will depending on the inner diameter of the CLASS ‘A’ chimney that this appliance is to be vented into.

Place a bead of high temperature silicone or Mil-Pac at each connection to ensure a tight seal.

NOTE: An approved 4” (10 cm) diameter flex liner must be used in the application.

NOTE: Use Simpson Dura Vent from the top of the appliance until this vent reaches the CLASS ‘A’ chimney. Install the retro adapter to the top section of GS direct vent pipe and install the flex liner to the retro adapter.

Fully line the CLASS ‘A’ chimney with a minimum 4” (10 cm) flex liner to the top of the CLASS ‘A’ chimney.

Place a bead of high temperature silicone to the Simpson Cap adapter and securely attach the flex liner to the adapter.

Secure the cap adapter to the CLASS ‘A’ chimney ensuring an airtight seal.

Install the vertical termination cap.

Light the unit and ensure proper operation.

THE USE OF ANY EXISTING CHIMNEY AS AN AIR INTAKE

IS NOT COVERED UNDER THE ANSI Z21.88-2002 CSA

2.33a-2002 TEST METHODS AND THE RESULTING ITS/WH

PRODUCT CERTIFICATION. THE CODE AUTHORITY HAVING

JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD.

Figure 36: Assembly of Venting into a Class

‘A’ Chimney.

26

Image 26
Contents EG28 DV Safety Precautions GeneralTable of Contents Codes And Approvals This Enviro EG28 DV FireplaceSpecifications EG28 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsComponent Sound & Reason Pilot BurningMaintenance and Service Removing the DoorTurn the unit off, allow it to cool down completely Way, and snap into place Kit Parts ListConversion Kit Installation Must be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH EG28 DV Wiring Diagram Min. Manifold Pressure Natural Gas Propane Main OrificeManifold Pressure Max Supply PressureSecondary Installation Log PlacementLog Placement with Embers Trouble Shooting Problem Possible Cause SolutionParts List Reference Part Description NumberReference Number Part Description Part Number Parts Diagram Chassis EG 28 Gas Tray and Door Assemblies Warranty To the DealerWarranty Warranty Installation Data Sheet