Initial Installation

QUALIFIED INSTALLERS ONLY

WARNING:

Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

PREPARATION FOR INSTALLATION:

Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible.

Before beginning, carefully check the glass door and the log set

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building; e.g. cutting a wall or ceiling joist.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8 m) of the stove.

The flow of combustion and ventilation air must not be obstructed.

CLEARANCES TO COMBUSTIBLES:

A. Sidewall to unit

10 inches

(25.4 cm)

B. Backwall to unit

4 inches

(10.2 cm)

C. Corner to unit

2 inches

(5.1 cm)

D. Combustibles to unit top

22 inches

(55.9 cm)

E. Floor to unit

0 inches

(0 cm)

F. Alcove maximum depth:

48 inches

(121.9 cm)

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

��

��

���� ���

��� ���

���

 

���� ���

 

Figure 13: Clearances to combustibles.

12

Image 12
Contents EG28 DV Safety Precautions GeneralTable of Contents Codes And Approvals This Enviro EG28 DV FireplaceSpecifications EG28 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsComponent Sound & Reason Pilot BurningMaintenance and Service Removing the DoorTurn the unit off, allow it to cool down completely Kit Parts List Conversion Kit InstallationWay, and snap into place Must be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH EG28 DV Wiring Diagram Natural Gas Propane Main Orifice Manifold PressureMin. Manifold Pressure Max Supply PressureSecondary Installation Log PlacementLog Placement with Embers Trouble Shooting Problem Possible Cause SolutionParts List Reference Part Description NumberReference Number Part Description Part Number Parts Diagram Chassis EG 28 Gas Tray and Door Assemblies Warranty To the DealerWarranty Warranty Installation Data Sheet

EG28-120, EG28 DV specifications

The Enviro EG28 DV and EG28-120 are cutting-edge devices designed for enhancing environmental monitoring and improving overall efficiency in various applications. These units are part of Enviro's commitment to sustainable innovation, catering to industries such as agriculture, industrial processes, and smart cities.

One of the standout features of the Enviro EG28 DV is its advanced sensor technology. This device is equipped with high-precision sensors that can measure a range of environmental parameters, including air quality, temperature, humidity, and even soil metrics. The ability to gather diverse data points in real-time allows users to make informed decisions, ultimately leading to better resource management and environmental conservation.

The EG28-120 variant takes this a step further with its enhanced connectivity options. It supports various communication protocols, including Wi-Fi, Bluetooth, and cellular networks, ensuring seamless integration into existing systems. This connectivity not only facilitates remote monitoring but also enables data sharing across different platforms, making it easier for stakeholders to access crucial information and collaborate effectively.

Both models boast user-friendly interfaces, complete with intuitive dashboards that simplify data visualization. Users can easily track readings, analyze trends, and generate reports, which is essential for regulatory compliance and performance assessment. The devices are also complemented by mobile applications, allowing for on-the-go monitoring and alerts, thus promoting proactive management of environmental factors.

Durability is another critical aspect of the Enviro EG28 DV and EG28-120. Designed to withstand challenging conditions, these devices feature rugged exteriors and are resistant to dust and water, ensuring reliable performance in various environments. Their low power consumption is an added advantage, making them suitable for long-term deployment without frequent maintenance.

In summary, the Enviro EG28 DV and EG28-120 stand out for their advanced sensor capabilities, versatile connectivity, user-friendly design, and robust durability. These features make them invaluable tools for monitoring environmental conditions, supporting industries in their quest for sustainable practices and efficient resource management. With their innovative technologies, these devices are poised to play a significant role in shaping the future of environmental stewardship.