Install the Optional Ash Door Heat Shield
Many installations will require the use of the supplied ash door heat shield. Refer to the “Floor Protection” sections starting on Page 10 to determine if your instal- lation requires the use of the ash door heat shield.
1.Remove the two Phillips pan head screws from the ash door.
2.Insert the screws through the ash door heat shield (from the painted side), place the 5/16” spacers over the screws, and carefully thread them back into the original holes. (Fig. 23) The curved lip should be upward, under the ashlip of the stove.
3.Tighten securely.
Spacers
ST538
Fig. 23 Install the ashdoor heat shield.
Adjust the Leg Levellers
Lift the stove slightly so there is no weight on the leg while making the adjustment.
Reverse the Flue Collar (If necessary)
Reverse the flue collar by removing the two screws that attach it to the back of the stove. Be sure the gasket around the flue collar opening is in position when you screw the collar back onto the stove.
Defiant 1610
Attach the Damper Handle
Use the 1/4”
Attach the Primary Air Thermostat Handle
The primary air thermostat handle is the smaller of the two black handles. Secure the handle to the stub on the right side of the stove with an
Assemble the Removable Insert Handle
The ceramic removable insert handle opens and closes the front doors. Remove after each use, and store it in the handle holder behind the right front leg. Assemble the handle by passing the 3³⁄₈" screw through the ceramic shaft and into the bright metal nub. (Fig. 25) Tighten carefully until snug.
ST539
Fig. 24 Attach the thermostat handle.
ST540
Fig. 25 Assemble the front door handle.
30002850 | 21 |