Enviro EG28-120 owner manual Codes And Approvals, This Enviro EG28 DV Fireplace

Page 4

Codes And Approvals

DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 feet (610 m) is to be reduced 4% for each 1000 feet (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (EG28 DV NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO EG28 DV Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)

Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

• Manufactured (mobile) home installation must be in accordance with the Manufactured Home Construction and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A. The unit must be bolted to the floor of the mobile home and must be electrically grounded to the steel chassis.

Are approved for installation on combustible materials (i.e. Wood, carpet or linoleum).

Is not approved for closet or recessed installations.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

4

Image 4
Contents EG28 DV Safety Precautions GeneralTable of Contents Codes And Approvals This Enviro EG28 DV FireplaceSpecifications EG28 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsComponent Sound & Reason Pilot BurningMaintenance and Service Removing the DoorTurn the unit off, allow it to cool down completely Conversion Kit Installation Kit Parts ListWay, and snap into place Must be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH EG28 DV Wiring Diagram Natural Gas Propane Main Orifice Manifold PressureMin. Manifold Pressure Max Supply PressureSecondary Installation Log PlacementLog Placement with Embers Trouble Shooting Problem Possible Cause SolutionParts List Reference Part Description NumberReference Number Part Description Part Number Parts Diagram Chassis EG 28 Gas Tray and Door Assemblies Warranty To the DealerWarranty Warranty Installation Data Sheet

EG28-120, EG28 DV specifications

The Enviro EG28 DV and EG28-120 are cutting-edge devices designed for enhancing environmental monitoring and improving overall efficiency in various applications. These units are part of Enviro's commitment to sustainable innovation, catering to industries such as agriculture, industrial processes, and smart cities.

One of the standout features of the Enviro EG28 DV is its advanced sensor technology. This device is equipped with high-precision sensors that can measure a range of environmental parameters, including air quality, temperature, humidity, and even soil metrics. The ability to gather diverse data points in real-time allows users to make informed decisions, ultimately leading to better resource management and environmental conservation.

The EG28-120 variant takes this a step further with its enhanced connectivity options. It supports various communication protocols, including Wi-Fi, Bluetooth, and cellular networks, ensuring seamless integration into existing systems. This connectivity not only facilitates remote monitoring but also enables data sharing across different platforms, making it easier for stakeholders to access crucial information and collaborate effectively.

Both models boast user-friendly interfaces, complete with intuitive dashboards that simplify data visualization. Users can easily track readings, analyze trends, and generate reports, which is essential for regulatory compliance and performance assessment. The devices are also complemented by mobile applications, allowing for on-the-go monitoring and alerts, thus promoting proactive management of environmental factors.

Durability is another critical aspect of the Enviro EG28 DV and EG28-120. Designed to withstand challenging conditions, these devices feature rugged exteriors and are resistant to dust and water, ensuring reliable performance in various environments. Their low power consumption is an added advantage, making them suitable for long-term deployment without frequent maintenance.

In summary, the Enviro EG28 DV and EG28-120 stand out for their advanced sensor capabilities, versatile connectivity, user-friendly design, and robust durability. These features make them invaluable tools for monitoring environmental conditions, supporting industries in their quest for sustainable practices and efficient resource management. With their innovative technologies, these devices are poised to play a significant role in shaping the future of environmental stewardship.