Enviro 50-1574 technical manual Venting horizontally with rise

Page 14

Installation

Follow vent manufacturer’s guidelines for installation of venting. High temperature sealant must be used when connecting the vent pipe to the unit’s starter pipe. Improper seals at the vent joints may cause combustion byproducts to leak into the room where installed - seal as required..

THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION- RECOMMENDED:

A 45° down elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).

���� �������

����������� ���

�������� ���� �������

�������� �������

�� ���� ����

���� �������

�� �

Figure 12: Venting horizontally with rise.

THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS:

A 45° down elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).

Installation to use if there is a concrete or retaining wall in line with exhaust vent on pellet stove.

The termination must be 305mm (12”) from the outside wall and 305mm (12”) above the ground.

Horizontal frame

Termination cap

for thimble

 

Wall thimble

 

90o elbow

 

Wall framing

 

Vertical section

 

of vent pipe

 

 

Concrete Wall

EF 5

Clean out tee

Figure 13: Venting with concrete wall behind unit .

14

Image 14
Contents Evolution Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Installation Screws to take out to remove stove from palletImportant When not installing Minimum Alcove height 1220mm Installing Hearth Pad Pedestal onto Evolution Letter Minimum Clearance Description Exhaust Starter Tube can be installed 2 ways Exhaust LocationFresh Air Intake Airflow around the structure Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 NEW Zealand Special Notes Stove will not start TroubleshootingStove will not operate when hot Light # 2 on Heat output bar flashing 93C 200F high limit temperature sensor has trippedExhaust motor will not function normally Ignitor- the pellets will not light Control settings Heat Level has no effect on the fireConvection blower will not function normally Stove keeps going outWiring Diagram Parts List Reference # DescriptionParts List Parts Diagram Components Parts Diagram Steel Installation Data Sheet Name of Owner Address