Enviro 50-1574 technical manual Important When not installing

Page 7

 

 

 

Installation

 

 

 

DIMENSIONS:

 

 

 

 

 

 

 

 

 

Unit Dimensions

 

 

 

 

 

Height:

840 mm

(33 1/16”)

 

 

 

 

Width:

565 mm

(22 1⁄4”)

 

 

 

27 7/8"

Depth:

539 mm

(21 1⁄4”)

 

 

 

(708 mm)

 

 

 

 

 

 

 

Hearth Pad:

 

IMPORTANT: When not installing

 

Width:

619 mm

(24 3⁄8”)

 

Depth:

708 mm

(27 7⁄8”)

the optional Hearth Pad on the

 

 

 

 

unit,

the minimum

requirements

24 3/8" (619 mm)

 

 

 

for

protection on

combustibles

 

21 1/4"

 

22 1/4" (565 mm)

 

 

floors are a width of 620mm

(539 mm)

 

 

 

 

 

(243⁄8”) & depth of 670mm

 

 

 

 

(263⁄8”) under the unit.

 

 

 

 

 

 

 

33 1/16"

 

 

5 13/16"

 

 

 

(840 mm)

 

 

(147 mm)

 

 

 

 

 

26 3/8" (670 mm)

 

 

 

Figure 1: Dimensions of Evolution.

 

Table 1: Evolution Specifications.

Classification

Testing Standard

Description

 

 

 

 

 

Class I IP-20

EN14785:2006/EN13240:2001/A2:2004

Residential Wood Pellet Heater

 

 

 

 

 

 

 

 

 

 

Voltage

Current

Frequency

 

 

 

 

 

220 - 240 V

2.0 - 2.3 Amps

50 Hz

 

 

 

 

 

 

 

 

 

 

Maximum Power Requirement

Fuel type

Calorific value of Pellet used

 

 

 

 

 

525W (1793 BTU/hr)

wood pellets - 6mm (1⁄4”) dia.

≥ 5.10 kWh/kg (≥ 7900 BTU/lb)

 

 

 

 

 

 

 

 

 

 

Maximum Flue Gas Temperature

Mean Flue Gas Temperature

Mean Flue Gas Temperature (Reduced)

 

 

 

 

 

200°C (392°F)

192°C (378°F)

143°C (289°F)

 

 

 

 

 

 

 

 

 

 

Nominal Heat Output

CO emissions from Combustion

Energy Efficiency

 

 

 

 

 

7.6 KWh (25932 BTU)

0.032%

 

 

84%

 

 

 

 

 

 

 

 

 

 

Reduced Heat Output

CO emissions from Combustion (Reduced Output)

Energy Efficiency (Reduced Output)

 

 

 

 

 

3.2 KWh (10919 BTU)

0.045%

 

 

75%

 

 

 

 

 

 

 

 

 

 

CO2 at Nominal Output

Nominal Fuel Consumption Rate

Unit with Full Hopper

8.35%

1.78 Kg/hr (3.95 lb/hr)*

~ 140kg (310lb)

 

 

 

 

 

CO2 at Reduced Output

Fuel Consumption Rate (Reduced Output)

Hopper Capacity

3.45%

0.83 Kg/hr (1.85 lb/hr)*

~ 40kg (90lb)

*Note: Consumption will vary with the type of fuel used.

7

Image 7
Contents Evolution Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Screws to take out to remove stove from pallet InstallationImportant When not installing Minimum Alcove height 1220mm Installing Hearth Pad Pedestal onto Evolution Letter Minimum Clearance Description Exhaust Location Exhaust Starter Tube can be installed 2 waysFresh Air Intake Airflow around the structure Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit EF5 NEW Zealand Special Notes Stove will not operate when hot TroubleshootingStove will not start Exhaust motor will not function normally 93C 200F high limit temperature sensor has trippedLight # 2 on Heat output bar flashing Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not lightWiring Diagram Reference # Description Parts ListParts List Parts Diagram Components Parts Diagram Steel Name of Owner Address Installation Data Sheet