Installation

RATING LABEL LOCATION:

The rating label is located on the inside of the ash pan cover.

DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:

1.Check clearances to combustibles.

2.Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace.

3.Do not install the stove in a bedroom.

4.You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal chimney (must be lined if the chimney is over 15 cm (6”) diameter, or over 180 cm² (28 inches²) cross sectional area). An interior vent can be used with approved pipe passing through the ceiling and roof.

5.Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation.

6.The power cord is 2.43 m (8 feet) long and may require a grounded extension cord to reach the nearest electrical outlet.

REMOVING PELLET STOVE FROM PALLET:

Remove the two (2) wood screws (one on either side of the unit) to remove the unit from the pallet.

1.Remove the right and left hand cabinet sides by loosening the three (3) T-20 Torx screws on the back of the each panel.

2.Remove the one (1) screw located on the front of the cabinet side, behind the top louvers and one (1) screw behind the ash door.

3.Remove the two (2) wood screws that are holding the bottom of the stove to the pallet.

4.Close the side panels.

Figure 1: Screws to take out to remove stove from pallet.

6

Image 6
Contents Evolution Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Installation Screws to take out to remove stove from palletImportant When not installing Minimum Alcove height 1220mm Installing Hearth Pad Pedestal onto Evolution Letter Minimum Clearance Description Exhaust Starter Tube can be installed 2 ways Exhaust LocationFresh Air Intake Airflow around the structure Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 NEW Zealand Special Notes Troubleshooting Stove will not operate when hotStove will not start 93C 200F high limit temperature sensor has tripped Exhaust motor will not function normallyLight # 2 on Heat output bar flashing Ignitor- the pellets will not light Control settings Heat Level has no effect on the fireConvection blower will not function normally Stove keeps going outWiring Diagram Parts List Reference # DescriptionParts List Parts Diagram Components Parts Diagram Steel Installation Data Sheet Name of Owner Address