Enviro 50-1574 technical manual NEW Zealand

Page 20

Installation

THERMOSTAT INSTALLATION:

1.Install the wall thermostat (12 or 24 Volt rated) in a location that is not to close too the unit but will effectively heat the desired area.

2.Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat.

If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator. If the heat in the room becomes to great, the high limit switch may turn the stove off and the switch will have to be manually reset. To reset the high limit switch, remove the right cabinet side. The switch is found behind the control panel. Avoid setting off the high limit switch.

Figure 23: Thermostat wire placement.

OPTIONAL SLIDER/DAMPER INSTALLATION:

 

NOTE: NOT APPLICABLE FOR GERMANY AND

 

NEW ZEALAND

 

Slider damper

If you wish to adjust the slider damper externally (NOT

rod and knob

 

REQUIRED), please follow the instructions below.

 

 

 

7/16" Nut

 

 

7/16" Clinching Nut

 

 

Slider damper plate

 

Figure 24: Slider/Damper Assembly.

 

1. To install the OPTIONAL slider damper rod, remove the left cabinet

 

side and locate the slider damper plate. Install the 7/16” (11mm)

Slider/

nut onto the slider damper rod, thread all the way to the end of

Damper

the threads on rod.

 

Knob

 

 

2. Slide rod through the hole in the slider damper plate and install

 

the 7/16” (11mm) clinching nut onto the rod and tighten completely

 

onto the slider damper plate.

 

 

3. Re-install the cabinet side. Install the black knob on the end of the

Figure 25: Slider/Damper Knob.

rod. Check slider damper for smooth operation.

 

 

 

20

Image 20
Contents Evolution Table of Contents Safety Warnings & Recommendations Safety Warnings & Recommendations Safety Warnings & Recommendations Installation Screws to take out to remove stove from palletImportant When not installing Minimum Alcove height 1220mm Installing Hearth Pad Pedestal onto Evolution Letter Minimum Clearance Description Exhaust Starter Tube can be installed 2 ways Exhaust LocationFresh Air Intake Airflow around the structure Venting horizontally with rise Inside Vertical Installation Outside Vertical Installation Through vent hole Exterior Blower KitThrough Wall Installation with Exterior Blower Kit EF5 NEW Zealand Special Notes Stove will not start TroubleshootingStove will not operate when hot Light # 2 on Heat output bar flashing 93C 200F high limit temperature sensor has trippedExhaust motor will not function normally Control settings Heat Level has no effect on the fire Convection blower will not function normallyIgnitor- the pellets will not light Stove keeps going outWiring Diagram Parts List Reference # DescriptionParts List Parts Diagram Components Parts Diagram Steel Installation Data Sheet Name of Owner Address