To replace brushes, first remove solu- tion tank (Fig.
With handle in upright position, tilt cleaner back so that it rests on the floor.
Align post (C) on brush block with hole (D) on bottom of cleaner. Turn brushes slightly until post fits easily into hole.
Press brush assembly firmly to snap into place.
Cleaning the Nozzle
Turn cleaner OFF and disconnect from electrical outlet.
The cleaner’s nozzle (E) can be removed for easy cleaning.
F
E
F
HI
G
Slide the two nozzle release latches
(F) outward.
Remove nozzle (E) by pulling straight out.
Rinse nozzle under running water. Remove debris from squeegee (G) and wipe with a damp cloth.
To replace nozzle, make sure latches are out.
Align middle section (H) of nozzle with opening (I) on cleaner.
While holding nozzle in place, slide latches inward to lock in place.
Storage
Before storing cleaner:
Turn cleaner OFF and disconnect from electrical outlet.
•Empty and rinse solution and recov- ery tanks. Allow to air dry.
•Allow filter in recovery tank lid to dry.
•Set the cleaner for “Dry Vacuuming” (pedal to “DRY” and Wet Control switch up).
•Make sure that nothing is pressing on the nozzle squeegee.
•Do not store cleaner on a wood sur- face unless cleaner is completely
dry. | Continued | 11 |
|