Bissell 83V5 Troubleshooting, Heat indicator light does not illuminate, Reduced spray or no spray

Page 16

Troubleshooting

WARNING:

To reduce the risk of electric shock, or injury, unplug from the outlet before servcing

Heat indicator light does not illuminate

Possible Causes

1.The heater switch is not turned on.

2.The machine power switch is not turned on.

Remedies

1.Turn on the heater switch located on side of unit.

2.Both switches must be on to activate the heat indicator light.

Reduced spray OR no spray

Possible cause

1.Bladder may be empty.

2.2-in-1 water tank may not be seated properly.

3.Pump may have lost prime.

4.The pump belt may be broken.

A.

B.

Remedies

1.Turn power switch off; refill bladder with clean hand hot tap water and formula.

2.Turn power switch off; remove tank and reseat.

3.Turn power switch off; after 1 minute turn on and depress spray trigger.

4.Turn power switch off and unplug from the outlet. To check if a pump belt has broken, you will need a flat head screwdriver. A. Insert the blade end into the slot of the belt access door to release. Examine the belt for breakage. You should be able to see the pump belt looped around the motor shaft. If it is broken or missing, please refer to Replacement Parts on page 18. A replacement belt may be ordered by calling BISSELL Consumer Services. Complete installation instructions will accompany the replacement belt. B. When replacing belt access door be sure to line up slots of belt access door with slots in machine, slide door into place and snap shut.

Slots Pump Belt

16w w w . b i s s e l l . c o m

Image 16
Contents Users Guide 83V5 SeriesThanks for buying a Bissell Healthy Home Fresh Clean Reduce the risk of fire, electric shock, or injury Read all instructions before using your deep cleanerThis appliance must be Earthed Optional Accessories Ergonomically Designed Handle Handle Assembly Heater SwitchLower Body Assembly Belt Access Door Removable Nozzle DirtLifter PowerBrushCleaning formula Power Switch Large, Easy-To Maneuver WheelsCord Clip Tough Stain Tool Ready-to-Use Hose Handle ReleaseAssembly Operations Special features Scotchgard Protector Measuring cupIn-1 water tank Removable NozzleBefore you clean Pretreating optionalFill the bladder with clean hand hot tap water Fill the 2-in-1 water tankCarpet cleaning Handle Release Power Switch Heater SwitchReadyTools Empty the 2-in-1 water tank/clean removable nozzleCheck for colourfastness in an inconspicu- ous place Operations Thoroughly vacuum or sweep floor to pick up any debris Hard Floor CleaningPlace.4 Be sure the ReadyTools dial is set to Machine care Maintenance and careMachine storage Heat indicator light does not illuminate TroubleshootingReduced spray or no spray DirtLifter PowerBrush does not turn Cleaner not picking up solutionThank you for selecting a Bissell product Possible cause RemediesReplacement parts Accessories and formulasPart Name 203-0105 Lint ScreenWarranty Bissell Healthy Home Fresh Clean Limited Two Year WarrantyFor UK inquiries For all other inquiries Bissell Homecare, IncBissell consumer services If your Bissell product should require service