Installing the water heater:

CAUTION: Reinforcement of the wall is required in case the wall is not strong enough to hold the appliance.

 

 

1/8" (.32 cm)

 

 

Clearance

Upper Bracket

Wood

Washer

 

Screw

 

 

Wood

 

Screw

 

Washer

 

Wood

 

Screw

Lower Bracket

Mounting the Water Heater

Make sure the location of the appliance allows for easy access and operation.

Wall studs should be utilized when mounting the water heater to the wall. Alternately, a suitable piece of wood may be placed inside or outside of the wall to span the distance between the wall studs. Fasten the water heater mounting brackets to the wood.

In case of dry wall or concrete wall, use drywall anchors or lag bolts.

The water heater requires 120VAC/60Hz. Have a receptacle with ground terminal near the water heater. The length of the power supply cord is 10 feet (3 m) (indoor water heater only.)

Install a wood screw for the upper bracket with a clearance of 1/8” (.32 cm) between the wall and the screw head. Hang the center of the upper bracket on the screw.

Using a wood screw and a washer, affix the lower bracket to the wall (Left and Right). Repeat to affix the top bracket.

The brackets can be adjusted to change the distance between the back of the appliance and the wall within the range of 3/8” (.95 cm) to 1-1/2” (3.8 cm).

Loosen the adjustment screws of both the top and the bottom brackets to adjust the distance (See diagram below).

TOP

Bracket Adjustment Screws

Adjustment Screws

Bracket BOTTOM

Thermal Expansion

A thermal expansion tank will be required if the water heater is installed in a closed loop system to prevent damage to heater, related piping and relief valve. Replacing the relief valve will not correct the problem! The expansion tank is designed with an air cushion built in that compresses as the system pressure increases, thereby relieving the over pressure

condition and eliminating the repeated operation of the relief valve. Other methods of controlling thermal expansion are also available. Contact your installing contractor, water supplier or plumbing inspector for additional information regarding this subject.

IMPORTANT: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the internal components

of the water heater.

16

Water Supply Connections

Plumbing should be carried out by a qualified plumber in accordance with local codes.

Use approved plumbing materials only.

The diameter of the pipe lines should be a minimum of 3/4”.

To conserve energy and to prevent freezing, insulate both cold and hot water supply lines. DO NOT cover the drain or pressure relief valve.

To ensure proper operation of the water heater, the following water pressure guidelines should be followed:

Operation of the water heater requires the minimum water pressure of 14 psi (97 kPa) and a minimum water flow rate of 0.66 gpm (2.5 lpm).

A water pressure of 40 psi (276 kPa) is required to achieve maximum flow rate.

To maintain proper performance, ensure sufficient water supply pressure. The

Required Water Pressure = Min. Operating Water Pressure (14 psi [97 kPa]) + Pipe Pressure Loss + Faucet and Shower Pressure Loss + Safety Margin (more than 5 psi [34 kPa]).

To supply hot water to upper floors, additional water pressure (0.44 psi/ft [10 kPa/m]) must be ensured. The measurement should be calculated by the distance between the water inlet of the water heater (ground level) to the hot water faucet (upper floor level).

Well water systems should be set to ensure a minimum system pressure of 40 psi (276 kPa). The pressure should remain stable during the operation of the water heater.

When the water is supplied from a water supply tank, the height of the tank and the diameter of the pipes and their relation to water pressure should be taken into consideration. Gravity water pressure is not recommended.

Image 16
Contents Tankless Water Heater That will result in death or serious You can find them on a label on the applianceInjury Install and Properly Vent the Water HEATER… N G E R Natural GAS and Liquefied Petroleum Models Read and Follow this Safety Information Carefully Installing the Outdoor water heater Location of the Outdoor water heaterInstalling the Indoor water heater Location of Indoor Water HeaterCorrosive Atmospheres Combustion and Ventilation Air Indoor Water Heater OnlyInspect Shipment Venting Venting LengthsMaximum Vent Length Minimum Vent Length The ventingAppliance Vent Adapter Venting Through Closed SpacesDraining the Condensate Installing the water heater Horizontal Vent Terminal Location Indoor Water Heater Outdoor Water Heater Additional Considerations Vent Horizontal Wall Thimble Installation Vertical Vent Installation Vertical Vent Termination LocationThermal Expansion Mounting the Water HeaterWater Supply Connections Water Filter Clean Water Inlet Check Valve Nipple Relief Valve Leak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeRemote Control Installation ControlModel Description Range NumberRemote Control ExtensionWall CablePenetration Suitable Indoor water heaters only Electrical ConnectionIndoor or Outdoor water heaters Indoor Models Outdoor ModelsHot and Cold Pipe Insulation Installation During Installation of this water heater…Insulation Blankets Do’sInstallation Check List Lighting the water heater To Turn OFF GAS to ApplianceSafety Precautions Water Temperature SettingTime/Temperature Relationship in Scalds Operating the water heaterWater Temperature Setting… Housekeeping Routine Preventative MaintenanceDrain heater. See Draining Water Heater section on Venting System Inspection Burner InspectionVacation and Extended Shut-Down Condensate Trap InspectionDraining the Water Heater Freeze ProtectionBefore You Call For Service… Indoor Water Heater Only Outdoor Water Heater OnlyReplacement Parts Instructions For Placing a Parts OrderTemperature Setting DIP Switch Adjustment If YOU Need Service