INSTALLATION
DIMENSIONS AND TECHNICAL DATA
Model |
| 300 135 | 300 170 |
|
|
|
|
|
|
|
|
| |||||
| 620 130 |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Storage capacity | litres |
| 135 | 170 |
|
|
|
|
|
|
|
|
| ||||
Mass (tank) Empty | kg |
| 54 |
|
|
| 63 |
|
|
|
|
|
|
|
|
| |
Full | kg |
| 189 | 233 |
|
|
|
|
|
|
|
|
| ||||
Dimensions |
| A |
|
| B | C | D | E | F | G | H |
| K | L | M | ||
130 / 135 | mm | 1615 | 425 | 500 | 988 | 328 | 297 | 1490 | 58 | 490 | 213 | 75 | |||||
170 | mm | 1915 | 425 | 500 | 1213 | 403 | 297 | 1790 | 58 | 490 | 213 | 75 | |||||
|
|
|
|
|
|
|
|
|
|
| |||||||
Gas Details | Hourly Gas |
|
| Min. Gas | Test Point Gas |
|
| Max. Gas | |||||||||
Consumption (MJ) |
| Pressure (kPa) | Pressure (kPa) |
| Pressure (kPa) | ||||||||||||
|
|
| |||||||||||||||
| 130, 135 |
|
| 170 |
|
| 130 to 170 | 130, 135 |
| 170 |
| 130 to 170 | |||||
Natural | 30 |
|
|
| 30 |
|
| 1.13 |
| 1.00 |
| 1.00 |
|
| 3.50 |
| |
Propane | 30 |
|
|
| 30 |
|
| 2.75 |
| 2.70 |
| 2.70 |
|
| 3.50 |
| |
Butane | 25 |
|
|
| 25 |
|
| 2.75 |
| 2.70 |
| 2.70 |
|
| 3.50 |
| |
Town / TLP | 29/27 |
|
| 29/27 |
|
| 0.75 |
| 0.44 |
| 0.44 |
|
| 3.50 |
|
Model numbers: N = Natural, P = Propane, B = Butane, T = Town / TLP. Letter N, P, B or T is included in the model number, eg 300135N0, to denote gas type.
Specifications are subject to change with ongoing product improvements.
18