LIGHTING THE WATER HEATER

LIGHTING INSTRUCTIONS

Using the gas control light the water heater as follows:

1.Stop, read the safety information on page 24.

2.Turn the gas control knob fully clockwise to the “z” (off) position.

3.Wait five (5) minutes so any build up of unburnt gas can escape. If you then smell gas, stop and follow “C” in the safety information. If you do not smell gas, proceed to step 4.

4.Turn the knob to the “·” (pilot) position.

5.Depress the knob fully (until star disappears below housing) and after 30 seconds, whilst keeping the knob depressed, repeatedly press the igniter button (for up to 40 seconds) until the pilot flame ignites.

Warning: Keep your face clear of the combustion chamber opening while pressing the igniter.

Note: It is not possible to depress the knob fully if the gas control has activated its safety shut-off feature. In this case, wait 60 seconds for the gas control to reset.

6.Keep the knob depressed for 20 seconds after the pilot flame lights. The pilot can be checked by looking through the opening at the top of the front cover to view the flame in the reflector.

7.Release the knob and check the pilot is still alight.

8.If the pilot has failed to light or has not remained alight, turn the gas control knob to the "z” (off) position. Wait five (5) minutes for any unburnt gas to escape and then begin again at step 3.

Note: Failure to wait five (5) minutes may result in a fire or explosion.

9.When the pilot flame remains alight with the gas control knob released, turn the knob anticlockwise to the setting of ‘6’. This will give a water temperature of about 60°C.

10.Refer to “Temperature Adjustment” on page 4, if further temperature adjustment is required.

The main burner will now automatically ignite when heating is required and extinguish when the water has been heated to the set temperature. If the main burner does not light at the selected setting, the water may already be at the selected temperature.

Note: Never press the igniter button while the top knob is in a numbered position.

25

Image 25
Contents Owners Guide Installation Instructions Patents Contents About Your Water Heater Temperature AdjustmentModel Type HOW HOT should the Water BE?To Turn OFF the Water Heater SafetyDoes the Water Quality Affect the Water HEATER? To Turn on the Water HeaterHOW Long will the Water Heater LAST? Anode ProtectionMains Pressure HOW Your Water Heater WorksPiezo Ignition Pilot IgniterRegular Care Servicing Expansion Control ValveNot Enough HOT Water or no HOT Water Save a Service CallWater not HOT Enough Normal Operation Temperature Pressure Relief Valve RunningContinuous dribble Steady flows for long period often at nightWater Heater Appears to be Leaking CAN’T Light the Pilot FlameHigh GAS Bills Water Heater Location InstallationMains Water Supply Safe TrayHOT Water Delivery Tank Water SupplyCirculated HOT Water Flow and Return System Temperature Limiting DeviceAnode Types Reducing Heat LossesSaddling Pipe Work Gas Details Dimensions and Technical DataTypical Installation Indoor Location Connection Sizes Connections PlumbingWater Inlet and Outlet Pipe Sizes GAS InletRelief Valve Relief Valve Drain To Fill and Turn on the Water Heater CommissioningGAS Inlet Pressure Safety Information For Your Safety Read Before LightingLighting the Water Heater Lighting Instructions Using the gas control light the water heater as followsAIR Shutter Test the Water Heater After InstallationClose Down Procedure Draining the Water Heater This page is intentionally blank Anode Water SuppliesSaturation Index Warranty Exclusions Warranty ConditionsRheem will Warranty