GE AP13787 Leak Testing, Pressure Testing the Gas Supply System, High Altitude

Page 11

WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the type shown on the rating plate. Such conversion could result in hazardous operating conditions.

Safety Instructions

Gas Supply

The branch gas supply line to the water heater should be clean 1/2” black steel pipe or other approved gas piping material.

A ground joint union or ANSI design certified semi-rigid or flexible gas appliance connector should be installed in the gas line close to the water heater. The National Fuel Gas Code (NFGC) mandates a manual gas shut-off valve: See (NFGC) for complete instructions.

If flexible connectors are used, the maximum length shall not exceed 36”.

If lever type gas shut-offs are used, they shall be T-Handle type.

Compound used on the threaded joints of the gas piping must be of the type

resistant to the action of LP gas. Use compound sparingly on male threads only.

A sediment trap should be installed at the bottom of the gas line.

Do not use excessive force (over 31.5 ft lbs.) in tightening the pipe joint at the gas control (thermostat) inlet, particularly if teflon pipe compound is used, as the valve body may be damaged.

The inlet gas pressure to the water heater must not exceed 10.5” w.c. for natural gas, or 14” w.c. for LP gas. For purposes of input adjustment, the minimum inlet gas pressure (with main burner on) is shown on the water heater rating plate. If high or low gas pressures are present, contact your gas supplier for correction.

Installation Instructions Operating Instructions

WARNING: Never use an open flame to test for gas leaks, as property damage, personal injury, or death could result.

Leak Testing

The water heater and its gas connections must be leak tested at normal operating pressures before it is placed in operation.

Turn on the manual gas shut-off valve near the water heater.

Use a soapy water solution to test for leaks at all connections and fittings. Bubbles indicate a gas leak that must be corrected.

The factory connections to the gas control (thermostat) should also be leak tested after the water heater is placed in operation.

Care and Cleaning

Pressure Testing the Gas Supply System

The water heater and its manual gas shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 3/8 psi

(10.5” w.c.) for natural gas, or 1/2 psi (14” w.c.) for LP gas.

The water heater must be isolated from the gas piping system by closing the manual gas shut-off valve during any pressure testing of the gas supply piping at pressures equal to or less than

3/8 psi (10.5” w.c.) for natural gas, or 1/2 psi (14” w.c.) for LP gas.

WARNING: Failure to install a water heater suitable for the altitude at the location it is intended to serve, can result in improper operation of the appliance resulting in property damage and/or, producing carbon monoxide gas, which could result in personal injury, or death.

High Altitude

Input rating of this water heater is based on sea level operation. At higher elevations the actual input rate may be lower than the value listed on the rating label. This water heater can be installed at elevation up to 7,700 feet without any change or modification.

Installations above 7,700 feet are not authorized.

Contact the local gas supplier for more information.

11

Troubleshooting Tips Customer Service

Image 11
Contents Do not try to light any appliance With Installation Instructions for the InstallerResidential 40 and 50 Gallon Rheem Manufacturing CompanyFor Your Records R N I N G For Hot Water Scalds Water Temperature Time To Produce a Serious Burn120F 90F 160F Vacation Setting Safety Instructions Installation Customer Service Troubleshooting Tips Care and CleaningFront Sides Rear Top Installing the water heaterLocation Corrosive Atmospheres Customer ServiceInspect Shipment Combustion and Ventilation AirWater Supply Connections Typical InstallationCleaning Troubleshooting Tips Customer Service Thermal ExpansionCondensation Care and Cleaning OperatingRelief Valve To Fill the Water HeaterGas Supply Leak TestingPressure Testing the Gas Supply System Troubleshooting Tips Customer ServiceVenting Blower Assembly InstallationIf not factory installed Customer Service TroubleshootingVenting information for 3 Vents Maximum and Minimum Vent LengthsVenting information for 2 Vents Operating Care and CleaningHorizontal Vent Terminal Location Additional ConsiderationsVertical Vent Termination Location Horizontal Vent InstallationVertical Vent Installation Instructions Care and CleaningCementing Joints Cleaner-Primer and Medium Body Solvent CementDraining the Condensate Service WiringInsulation Blankets Heat Trap Hot and Cold Pipe Insulation InstallationDuring Installation of this water heater Water Supply Installation ChecklistWater Heater Location Combination Potable and Space Heating Application Care and Cleaning Troubleshooting TipsLighting the water heater Troubleshooting Tips Customer Service Safety PrecautionsOperating Procedure Installation Instructions Operating120F Water Temperature Setting…Water Temperature Draining the Water Heater Routine Preventative MaintenanceInstructions Installation Instructions SafetyBurner Inspection Installation Instructions SafetyHousekeeping Venting System InspectionAnode Rod Vacation and Extended Shut-DownBefore You Call For Service… Noise or draining Rumbling noiseRelief valve Producing poppingSecond Seconds Gas Valve LED Error CodesInstructions For Placing a Parts Order Replacement PartsBurner Assembly Kit Operating Instructions Care and CleaningInstallation Instructions Troubleshooting Tips If YOU Need Service Please place in envelope and mail to Consumer Product Ownership Registration If you require service, call

AP13787 specifications

The GE AP13787 is a smart and innovative appliance that has quickly gained attention for its advanced features and modern technologies. This product exemplifies GE's commitment to providing consumers with high-quality and efficient home solutions. The GE AP13787 stands out in the market, particularly due to its combination of functionality, energy efficiency, and user-friendly design.

One of the primary features of the GE AP13787 is its cutting-edge smart technology, which integrates seamlessly with smart home systems. This appliance is equipped with Wi-Fi connectivity, allowing users to control it remotely through a smartphone application. This capability enhances convenience, as consumers can monitor and adjust settings from anywhere, whether they are at home or on the go. The smart diagnosis feature also adds value, enabling users to troubleshoot potential issues quickly, minimizing downtime, and ensuring the appliance operates optimally.

In addition to its smart capabilities, the GE AP13787 boasts energy-efficient performance, an increasingly vital consideration for eco-conscious consumers. The appliance is designed to reduce energy consumption without sacrificing performance, helping users save on utility bills while also promoting sustainability. Its Energy Star certification is a testament to its efficiency, reflecting GE’s emphasis on responsible manufacturing and environmental stewardship.

Another notable characteristic of the GE AP13787 is its spacious and thoughtful design. It features ample storage and organization options, enabling users to maximize their kitchen space effectively. With adjustable shelves, clear bins, and easy-access compartments, finding and storing food items becomes a hassle-free experience.

Moreover, the GE AP13787 includes advanced cooling technologies that ensure optimal food preservation. Its Precision Temperature Management system keeps food at ideal temperatures, while the advanced air circulation technology promotes even cooling throughout the appliance. This feature is especially beneficial for maintaining the quality of perishables, extending their shelf life.

Overall, the GE AP13787 delivers a blend of modern technology, energy efficiency, and practical design. It is a perfect addition to any contemporary kitchen, catering to the demands of today’s consumers who seek convenience and quality. As the market for smart home appliances continues to grow, products like the GE AP13787 illustrate how innovation can enhance everyday living while being mindful of environmental impact.