INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using log heater. This will help circulate the heat from your log heater throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

NOTICE:Stateorlocalcodesmay only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated.Adirty chimney flue may create and distribute soot within house. Inspect chimney flue and firebox for damage. If damaged, repair flue and firebox before operating heater.

WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fire- place. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance (Variable Manually- Controlled Models Only) (see page 11)

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42 inches from the front, top or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids,oilorkerosenelamps,etc.)in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

8

www.desatech.com

113097-01C

Image 8
Contents What to do if YOU Smell GAS Patent PendingTable of Contents Safety Information Local Codes Est edition of The National Fuel Gas Code, Ansi Z223.1/NFPAUnpacking Product FeaturesProduct Identification Determining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeSide Wall Minimum FireboxLog DepthAccessories, Mantel ClearancesInstalling Damper Clamp Accessory for Vented Operation Floor ClearancesInstalling Heater Base Assembly Installation Items NeededChimney Minimum Permanent Area of Various Standard Round FluesConnecting to GAS Supply Attaching Base Assembly to Fireplace Floor Dual Burner ModelAdjustment. Checking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Logs Installing Front Log #1 CCL3930PTB/NTB ShownInstalling Crossover Log #4 CCL3930PTB/NTB Shown Installing Front Log Operating Heater Lighting InstructionsManual Lighting Procedure Variable Control OperationTo Turn OFF GAS To Appliance Shutting Off HeaterOperating Heater Thermostat Control Operation Control Knob and IgnitorCleaning Maintenance Inspecting BurnersService Hints Technical ServiceWhen Gas Pressure Is Too Low LogsTroubleshooting Observed Problem Possible Cause RemedyOr replace burner orifice Gas leak. See Warning Statement aboveOptional Positioning Thermostat Sensing Bulb For Masonry and FACTORY- Built Metal FireplaceDual Burner Biltmore Split OAK Models Single Burner Seasonal OAK ModelsIllustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Biltmore Split OAK ModelsIllustrated Parts Breakdown THERMOSTATICALLY-CONTROLLED Biltmore Split OAK Models Peg positions vary according to model 111340-02 111340-02 111340-01 Front Log #1 3A 3B Variable MANUALLY-CONTROLLED Seasonal OAK Models Replacement Parts AccessoriesParts Central Limited Warranty Comfort Glow VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

CRL2718PA/NA, CRL3124PA/NA, CCL3018PA/NA, CCL3924PA/NA, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, 24", 30 specifications

Desa gas fireplaces are known for their innovative designs and advanced technologies, making them a popular choice among homeowners seeking both aesthetics and performance. Among the range of products, the models Desa 24", 30, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, CRL2718PA/NA, CRL3124PA/NA, and CCL3018PA/NA stand out due to their unique characteristics and features that enhance the home ambiance while providing efficient heating solutions.

One of the key features of these Desa models is their variable size offerings. With options like the 24" and 30" units, homeowners can choose the perfect fit for their space, whether it's a cozy corner or a focal point in the living room. The variety of sizes allows for flexibility in design, ensuring that each fireplace integrates seamlessly with the surrounding decor.

Moreover, these models are equipped with advanced heating technologies that improve energy efficiency. Many units feature dual fuel capabilities, allowing users to switch between natural gas and propane, which is ideal for adapting to different energy sources and preferences. This flexibility is coupled with a powerful output, providing substantial warmth while also being environmentally friendly.

The aesthetic appeal of Desa fireplaces cannot be overlooked. Models like CCL3018PTA/NTA and CCL3924PTA/NTA come with realistic flame effects that replicate a traditional wood-burning fireplace's ambiance without the hassle of keeping wood stocked. The captivating flame patterns and ember beds create a warm and inviting atmosphere, enhancing any living space.

In terms of safety and convenience, Desa fireplaces are designed with several features that ensure hassle-free operation. Most models include electronic ignition systems, allowing for easy start-up without the need for matchsticks or lighters. Additionally, many units come equipped with remote controls, enabling users to adjust settings such as flame height and heat output from the comfort of their seats.

The construction of Desa fireplaces also emphasizes durability and quality. Built with robust materials and carefully engineered components, these fireplaces are designed to withstand the test of time while maintaining high-performance standards.

Overall, the Desa lineup, featuring models such as CCL3930PTB/NTB, CRL2718PA/NA, and CRL3124PA/NA, brings together a perfect blend of efficiency, aesthetic appeal, and modern technology. The thoughtful design, user-friendly features, and versatile options make them a fantastic choice for anyone looking to upgrade their home heating solution while adding a touch of elegance to their interiors. With a Desa fireplace, homeowners not only invest in a reliable source of heat but also enrich their living environment with style and comfort.