Whirlpool KUIA18NNJ*11, KUIA15NRH*11, KUIA15PRL*11 manual Removing The Measured Fill Water Valve

Models: KUIA15PLL*11 KUIA18PNL*11 KUIA15NLH*11 KUIA15PRL*11 KUIA15NRH*11 KUIA18NNJ*11

1 74
Download 74 pages 21.98 Kb
Page 36
Image 36
REMOVING THE MEASURED FILL WATER VALVE

REMOVING THE MEASURED FILL WATER VALVE

Manual backgroundWARNING

Electrical Shock Hazard Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Unplug ice maker or disconnect power.

2.Turn water supply off to ice maker.

3.Open the ice maker door.

4.Remove the four hex-head screws from the front panel and remove the panel.

Front Panel Screws

Measured Fill Valve

5.Remove the two hex-head screws from the measured fill water valve bracket.

6.Place a pan or towel under the valve to catch water.

7.Disconnect the water inlet and outlet tub- ing from the quick disconnect fittings on the measured fill water valve.

Measured Fill Valve

Bracket

ScrewsManual background

8.Disconnect the two electrical connectors from the valve.

Outlet Tube

Inlet Tube

Two Electrical Connectors

4-16

Page 36
Image 36
Whirlpool KUIA18NNJ*11 Removing The Measured Fill Water Valve, Electrical Shock Hazard Disconnect power before servicing