REMOVING THE CONDENSER FAN MOTOR
WARNING
Electrical Shock Hazard Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug ice maker or disconnect power.
2.Open the ice maker door.
3.Remove the ice from the storage bin.
4.Disconnect the water and drain lines from the ice maker and remove the unit from its installation.
5.Remove the four
Front Panel Screws
6.Remove the two 5/16” screws from the front of the cabinet.
7.Remove two
8.Allow the valve to drop down out of the way.
Hot Gas Valve
Measured Fill Water Valve
|
| Water Inlet Tubing |
|
|
Screw | Screw |
NOTE: If the unit you are servicing is equipped with an internal drain pump, perform steps 9 and 10. If the unit does not have an internal pump, skip those steps, and proceed to step 11 on the next page.
9.From the back of the unit, remove the four screws from the unit compartment cover and remove the cover.
Unit Compartment Cover
4 Screws
Continued on the next page.