REMOVING THE CONDENSER FAN MOTOR

REMOVING THE CONDENSER FAN MOTOR

Manual backgroundWARNING

Electrical Shock Hazard Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Unplug ice maker or disconnect power.

2.Open the ice maker door.

3.Remove the ice from the storage bin.

4.Disconnect the water and drain lines from the ice maker and remove the unit from its installation.

5.Remove the four hex-head screws from the front panel and remove the panel.

Front Panel Screws

6.Remove the two 5/16” screws from the front of the cabinet.

7.Remove two hex-head screws from the measured fill water valve bracket.

8.Allow the valve to drop down out of the way.

Hot Gas Valve

Measured Fill Water Valve

 

 

Water Inlet Tubing

 

 

Screw

Screw

NOTE: If the unit you are servicing is equipped with an internal drain pump, perform steps 9 and 10. If the unit does not have an internal pump, skip those steps, and proceed to step 11 on the next page.

9.From the back of the unit, remove the four screws from the unit compartment cover and remove the cover.

Unit Compartment Cover

4 Screws

Continued on the next page.