REMOVING THE WATER RECIRCULATION PUMP
WARNING
Electrical Shock Hazard Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug ice maker or disconnect power.
2.Open the ice maker door.
3.Remove the ice from the storage bin.
4.Unscrew the drain cap from the reser- voir, drain the water, and replace the cap tightly.
5.Place a cloth in the drain hole to avoid hardware from falling inside.
Spacer Bracket (Left Side) 18˝ Models
Recirculation
Screw Pump Shield
Water Reservoir
ThumbscrewThumbscrew
6.Remove the
7.Disconnect the water fill tube from the pump mounting bracket.
8.Disconnect the two wire recirculation and drain pump connectors from the harness block.
9.Remove the two thumbscrews from the reservoir and remove the reservoir from the ice maker.
10.Remove the recirculation pump outlet tube.
11.Remove three
12.Separate the recirculation pump from the bracket.
2-Wire Connector
Water Fill Tube
Recirculation Pump
Outlet Tube
Drain Cap
Drain Pump